Troubleshooting Scenarios; Infiniband; Invalid Ip Address Entered For Swc Via Console Port; Bad Ib Cable - Cisco SFS-7012 - SFS InfiniBand Server Switch 7012 Hardware User's Manual

Server switch
Hide thumbs Also See for SFS-7012 - SFS InfiniBand Server Switch 7012:
Table of Contents

Advertisement

Appendix

Troubleshooting Scenarios

InfiniBand

This section documents common problems seen with the SFS 7012 switch.

Invalid IP Address entered for SWC via Console Port

Symptoms
Resolution / Workaround

Bad IB Cable

Symptoms
Resolution / Workaround

Improperly Seated IB Cable

Symptoms
Resolution / Workaround
OL-8787-04
Cannot access the Chassis Viewer browser window. The browser window times out and Chassis
Viewer will not come up.
Invalid IP Address entered for switch card via the console port. Make sure configuration is using a
valid IP address for the Switch (make sure initial configuration for switch is correct using the
console port during the boot sequence).
When viewing the IB fabric with a subnet manager viewer, no nodes will be seen, or only the nodes
that have a good IB connection will be seen.
Possibly a bad IB cable(s). Ensure that there is a Blue LED illuminated on the leaf module IB ports
of the SFS 7012 switch. Make sure that all devices (nodes) can be seen in the subnet manager
window.
When viewing the Subnet Manager no nodes will be seen, or only the nodes that have a good IB
connection will be seen.
Possibly an improperly seated IB cable(s). Ensure that there is a Blue LED illuminated on the
switch. Make sure that all devices (nodes) can be seen in your Subnet Manager window.