Description
Error - (The specified device) has not been
imported. Failed to start device.
Error importing device (with the specified
ID).
Error - Import failed. Retrying.
Error auto importing. Retry.
Error - Could not create subcontext:
cn=(The specified Context)
Error - (The given ESP) does not exist!
Error - Exception reading (the given ESP)
Remedy
Cause: The Identity Server was not properly
imported.
Action: Go to Access Gateway Server List
and click Repair Import. (The repair import.
functionality works for any server type.)
Otherwise, submit the
app_sc.0.log
for resolution.
Cause: The Server was not properly
imported.
Action: Go to Access Gateway Server List
and click Repair Import. (The repair import.
functionality works for any server type.) If this
fails, reinstall the server component.
Cause: Unable to communicate with the
Server being imported.
Action: Be sure the firewall is allowing port
1443 traffic. Otherwise allow the system to
retry for several minutes. If the server does
not appear in the Server List, click Repair
Import to resolve the issue. Otherwise,
submit the
app_sc.0.log
Cause: Unable to communicate with the
Server being imported.
Action: Be sure the firewall is allowing port
1443 traffic. Otherwise allow the system to
retry for several minutes. If the server does
not appear in the Server List, click Repair
Import. to resolve the issue. Otherwise,
submit the
app_sc.0.log
resolution.
Cause: Error creating Server object in config
store during import.
Action: Go to Access Gateway Server List
and click Repair Import. (The repair import
functionality works for any server type.)
Otherwise, submit the
app_sc.0.log
for resolution.
Cause: There was a error during the
Administration Console installation.
Action: Reinstall the Administration
Console.
Cause: The file required during the import
process could not be read.
Action: Be sure the indicated file can be
read by the novlwww user.