6 Message Reference
Parameter Description:
Board Status
Value
0x60
0x62
0x64
0x65
0x66
0x67
0x70
0x71
0x72
0x73
0x74
6.4.2
s7_mgt Completion Status Indication
Synopsis:
Message issued by s7_mgt on completion of initial configuration sequence.
Message Format:
Field Name
type
id
src
dst
rsp_req
hclass
status
err_info
len
80
Mnemonic
Description
SSDSI_RESET
Processor successfully reset.
SSDSI_FAILURE
Failure to reset board.
SSDSI_BRD_RMVD
Board removed (hot swap only).
SSDSI_BRD_INS
Board inserted (hot swap only).
SSDSI_LIC_FAIL
License validation failure.
SSDSI_LIC_CRP
License corruption.
SSDSI_BCONG_CLR
Message congestion towards board cleared.
SSDSI_BCONG_ON
Message congestion towards board occurred.
SSDSI_DIS_CLR
Message congestion discard towards board cleared.
SSDSI_DIS_ON
Message congestion discard towards board.
SSDSI_FAIL
Message congestion - board failure.
MESSAGE HEADER
Meaning
API_MSG_CNF_IND (0x0f09)
0
0xcf
Notification Module (see below)
0
0
Completion Status (see below)
Reserved for future use
0
Need help?