Adaptec 133U2 - AAA RAID Controller User Manual page 148

Ci/o management software
Table of Contents

Advertisement

Adaptec CI/O Management Software User's Guide
StatisticsCollectionInterval=
This variable specifies the interval at which system statistics will be
collected, assuming that the driver supports statistics collection.
Values must be entered as whole numbers. The default value is 1.
WarnAfterFirstPFAEvent=
If set to Yes, this variable specifies that if S.M.A.R.T. events (PFA) are
received from any drive the first event will be reported as a Critical
event and all events after that will be reported as Warning events. If
set to No, all S.M.A.R.T. events will be reported as Critical. The
default is Yes.
[TASKS]
TestAllSpares=
This variable schedules the Test All Spares operation. These jobs are
not written to the Scheduler Database and are scheduled every time
iomgr.nlm (NetWare) or iomgr.exe (Windows NT) is started. Valid
values are
Yes,H—Starts test every hour on the hour. For example,
TestAllSpares=Yes,H
Yes,D,Time—Starts test daily at a specified time (military time
format). For example, TestAllSpares=Yes,D,11:34. (The default
value is to test all spares daily at 2:00 A.M.)
Yes,W,Day of the week,Time—Starts test weekly at a specified
day and time (Day of the week: 0=Sun, 1=Mon, 2=Tues., etc.).
For example, TestAllSpares=Yes,W,2,11:34 (starts every week
on Tuesday at 11:34).
No—No tests are scheduled. For example, TestAllSpares=No.
[CAPABILITIES]
EnableRAID5=
This variable enables or disables the option of creating RAID 5
arrays. If it is set to No users cannot create RAID 5 arrays. Valid
values are Yes and No. The default is Yes.
A-8

Advertisement

Table of Contents
loading

This manual is also suitable for:

133u2

Table of Contents