Adaptec CI/O Management Software User's Guide
Note:
When the spare is created, Adaptec CI/O
Management Software should automatically start a
Reconstruct operation on the array. If for some reason
the reconstruct does not begin automatically, follow
the remaining steps to perform it manually.
7
Click
to open the Storage Configuration window. Right-
click on the Array icon that looks like this
Reconstruct from the drop-down menu. If the array has one
failed drive the Scheduler dialog box appears.
If you have a RAID 0/1 array with two or more failed disks,
and at least one disk of each mirrored pair is still good, a dialog
box appears with a list of the failed drives. You must
reconstruct the disks one-at-a-time, starting over each time at
the beginning of these steps. Select one of the drives on the list
and click OK; the Scheduler dialog box appears. (This assumes
that you have already physically replaced all of the failed
drives with good drives.)
8
Enter the required information for the Reconstruct operation in
the Scheduler dialog box. You can select Immediate to
reconstruct the drive immediately or select Schedule to
schedule the operation for a later time. (See Setting Scheduling
Options on page 8-2 for more information.)
9
Select an Execution Priority - high, medium, or low.
10
Click OK.
11
At the prompt, confirm that you want to reconstruct the array
member.
12
Read the event notifications that appear in the System Monitor
window (they may also appear as pop-ups on the screen) to
determine when the reconstruct is complete.
7-4