Appendix A - Specifications - Xantrex7 UX - REV A Owner's Manual

Inverter/charger
Table of Contents

Advertisement

Appendix A - Specifications

Input (DC)
Input Voltage (rated)
Input Voltage Range
Search Mode (typical)
On Mode (no load - idle)
Input (AC)
Input Voltage
Input Frequency
Input / Pass-through Current (max)
Output
Output Voltage (rms)
Output Frequency
Continuous Output Current
Continuous Power
Surge Capability
1 mSec
(1)
100 mSec
(2)
Peak Efficiency
Battery Charger
Maximum Charging Rate
Selectable Charging Rate (default)
Charger Type
Temperature Compensation
Electrical
AC Waveform
Power Factor Allowed
Voltage Regulation
Frequency Regulation
Load Sensing Range
Low Battery Cutout
High Battery Cutout
Physical
Enclosure Type
Temperature Range (specified)
Altitude Limit (operating)
Mounting
Wiring Requirements (AC)
Wiring Requirements (DC)
Wiring Requirements (ground)
Dimensions*
Weight
Standard Features
Easy-to-Use Control Panel
Circuit Protection
High and Low Battery Protection
Overtemperature Protection
Overcurrent Protection
Variable Speed, DC Cooling Fan
Options
BTS
RC8/50
BC5-4/0
BC5-2/0
Agency Approval
NOTES:
(1) Surge "1 mSec" - Maximum 1 ms peak output amps measured when starting AC loads
(2) Surge "100 mSec" - Maximum 100 ms peak output amps measured when starting AC loads
* Includes battery terminal covers, fan louvers, AC input breakers and ground lug
Specifications @ 25 °C Ambient
Specifications subject to change without notice.
©2002 Xantrex Technology Inc. All Rights Reserved.
P/N 975-0026-01-01 Rev A 06/2002
UX612
UX1112
12 VDC
12 VDC
10 to 16 VDC
10 to 16 VDC
<1 W
<1 W
5 watts
5.5 watts
120 VAC
120 VAC
60 Hz
60 Hz
30 A
30 A
120 VAC
120 VAC
60 Hz
60 Hz
3.4 A
5 A
400 VA
600 VA
25 A (peak)
38 A (peak)
22 A (rms)
22 A (rms)
92%
92%
25 A
50 A
Sealed Batteries:
14.3 VDC (Bulk) / 13.6 VDC (Float)
Vented Batteries:
14.7 VDC (Bulk) / 13.4 VDC (Float)
3-stage (Bulk, Absorption, Float)
with optional, plug-in sensor (BTS)
Modified sinewave
0.5 to 1.0
± 5% (at rated voltage)
± 0.01% (crystal regulated)
5 to 100 W (adjustable)
9.5 VDC
15.7 VDC
indoor, ventilated, steel chassis (with powdercoat finish)
0 °C to 25 °C
15,000 feet (5,000 meters)
wall or shelf-mount
#14 AWG (minimum) - depends upon model and wire length
#2 AWG (minimum) - depends upon model and wire length
#10 AWG (minimum) - depends upon model and wire length
6" H x 10.25" W x 15.5" D (15.2 cm H x 26 cm W x 39.4 cm D)
30 lb. (13.6 kg)
34 lb. (15.4 kg)
ON/OFF switch, LED display, load sensing potentiometer
front panel AC and charger circuit breakers
automatically shuts down batteries to prevent damage
automatically shuts down inverter to prevent thermal damage
automatically shuts down inverter to prevent damage
ensures maximum cooling under heavy loads (No fan provided on the UX512E or UX612 models)
Battery Temperature Sensor
on/off remote ON/OFF switch with status LED indicator and 50 foot (15 meter) cable
battery / inverter cable (5 foot - #4/0 AWG)
battery / inverter cable (5 foot - #2/0 AWG)
UL1741 1st Edition
UX1512
UX512E/SB
12 VDC
12 VDC
10 to 16 VDC
10 to 16 VDC
<1 W
<1 W
7 watts
5 watts
120 VAC
230 VAC
60 Hz
50 Hz
30 A
15 A
120 VAC
230 VAC
60 Hz
50 Hz
6.7 A
2.1 A
800 VA
500 VA
38 A (peak)
12 A (peak)
25 A (rms)
11 A (rms)
92%
92%
65 A
25 A
37 lb. (16.8 kg)
30 lb. (13.6 kg)
UX1112E/SB
12 VDC
10 to 16 VDC
<1 W
5.5 watts
230 VAC
50 Hz
15 A
230 VAC
50 Hz
4.8 A
1100 VA
14 A (peak)
11 A (rms)
92%
50 A
34 lb. (15.4 kg)
A-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ux series

Table of Contents