3.0 Installation

AC Wiring

WARNING: DISCONNECT
THE POWER FROM THE
UTILITY'S MAIN BREAKER
BOX BEFORE PROCEEDING.

Sub-panel Mounting

NOTE: Installations should be
performed by a qualified
person or a licensed
electrician following all
local and NEC codes.

Access to the Inverter's AC Terminal Block

CAUTION: The inverter's
AC output must never be
wired to the utility or
generator output. This
will cause severe damage
to the inverter which is
not covered under
warranty.
©2002 Xantrex Technology Inc. All Rights Reserved.
P/N 975-0026-01-01 Rev A 06/2002
• Determine the location of the sub-panel and install it according to the
manufacturer's directions.
• Install an appropriate-sized circuit breaker in the sub-panel based on the wire
size being used from the inverter output. This will later be wired to the inverter's
output.
All AC wiring connects to the terminal block located on the left-hand side of the
inverter.
• To access the terminal block, remove the two AC cover panels (if installed) by
removing the three Phillips screws. Units are shipped without the covers
installed (packed in a small plastic bag with additional hardware).
• Locate the AC input and output terminals on the block.
See Figure 3-11 on page 42 for AC input wiring.
See Figure 3-12 on page 43 for AC output wiring.
Figure 3-10
AC Access Covers and Hardware
Upper AC
Access
Panel
Lower AC
Access
Panel
39