3.0 Installation

Configuring the Inverter's Optional Battery Charger

Charger Configuration
Jumpers
EB
C
Location of the Optional Battery Charger Configuration Jumpers
©2002 Xantrex Technology Inc. All Rights Reserved.
P/N 975-0026-01-01 Rev A 06/2002
When equipped with an optional battery charger, the UX inverter has three
jumpers to control charger operation. A jumper is a small, rectangular piece of
plastic with two square holes in it, as shown in Figure 3-2a, that fit over two pins
as shown in Figure 3-2b. A jumper contains an internal conductor that joins the
two pins completing a circuit. When the jumper is removed, the circuit is
interrupted. Jumpers are often used for changing configuration parameters.
When a jumper is not connecting two pins, it can be stored by slipping it over
just one of the pins instead of both. This will have no effect upon the
configuration but will keep the jumper handy for future use.
The jumpers in the UX inverter are located on the main circuit board and are
labeled SEALED, DEEP, and UPS. To access the jumpers, remove the top cover
from the inverter following the instructions on page 28.
E15
E14
C108
Q37
C107
C56
R135
R137
U20
R139
C102
.047/630V
Figure 3-2a
Jumper Enlargement
Figure 3-2
Jumper
Pins
Figure 3-2b
Jumper Placement