Dimmer Switches; Fluorescent Lights; Heavy Loads; Microwave Ovens - Xantrex7 UX - REV A Owner's Manual

Inverter/charger
Table of Contents

Advertisement

5.0 Troubleshooting
Potential Problem Loads for the Inverter (continued)

Dimmer Switches

Fluorescent Lights

Heavy Loads

Microwave Ovens

Printers

CAUTION: Do not run a
laser printer using the UX
inverter for power.

Rechargeable Devices

Undersized Loads

©2002 Xantrex Technology Inc. All Rights Reserved.
P/N 975-0026-01-01 Rev A 06/2002
Most dimmer switches lose their ability to dim the lights when used with an
inverter and operate only in the fully ON or OFF position. Newer dimmer
switches controlled by microprocessors tend to work better in inverter
applications.
Some devices cannot be detected by the inverter's load sensor and will not
operate. Small fluorescent lights are the most common example. This can usually
be solved by plugging in an additional load.
If the battery-bank cannot deliver the necessary amperage to operate a heavy
load, the inverter will shut down. The battery voltage will then slowly rise back
above the low-voltage threshold causing the inverter to resume operation. This
cycling of the inverter will continue until the heavy load is reduced or an
additional source of power is added.
Microwave ovens are sensitive to peak output voltages. The higher the voltage,
the faster they cook. Since the inverter's peak output voltage is dependent upon
battery voltage and load size, the microwave's cook time may need to be
increased.
Most inkjet type printers work well in inverter applications. Laser printers,
however, require a high current for their fusing circuit and are not recommended
for use with an inverter.
When first using a rechargeable device, monitor its temperature for 10 minutes to
ensure it does not become abnormally hot. Excessive heat will indicate that it is
incompatible with the inverter.
If the power consumed by a device is less than the inverter's search mode
circuitry threshold, it will not run. This can usually be solved by plugging in an
additional load such as a 100-watt light bulb.