Bare wire
connections
Loop and
spade terminal
connections
L1 terminal
Neutral terminal
L2 terminal
Link removed
Ground screw
L2 wire
Green wire
White wire
Strain relief
4 Wire Appliance
Cord Connection
L2
Neutral
L1
14-50P Plug
Installation Instructions
L1 wire
Ground

Gas Connection

Make sure the gas supply valve is off and that the power to
the range is turned off at the circuit breaker or fuse box prior
to connecting the gas line.
Do not apply excessive pressure when tightening gas
connections and fittings.
Do not use Teflon tape or plumber's putty on gas flex line
connections.
Check for gas leaks as instructed below before using the
appliance. Do not use a flame to check for leaks.
For LP installations, the LP gas tank must have its own
high pressure regulator. This is in addition to the pressure
regulator provided with the range.
The maximum gas supply pressure to the regulator must
never exceed 1/2 pound per square inch (p.s.i.) or 3.5kPa.
The range and shut-off valve must be disconnected from the
gas supply piping during any pressure testing exceeding 1/2
p.s.i. (3.5 kPa).
The range must be isolated from the gas supply piping by
closing the shut-off valve during any pressure testing at or
below 1/2 p.s.i. (3.5 kPa).
Be careful not to damage the wires inside the chassis while
pushing the gas line through the access holes.
NOTE: The gas pressure regulator is pre-set at the factory for
the type of gas intended for use with the appliance. To verify that
the appliance is compatible with the type of gas available, check
the range rating label (see page 3 for location). Ranges intended
for use with LP gas will have "LP" as a part of the model number.
Consult your dealer if the range is not compatible with the type of
gas supplied.
1.
Make sure the gas supply valve is in the off position and
power to the range is off.
2.
Connect a flexible gas supply line to the gas shut-off valve
previously installed on the stub out. The gas line needs to be
long enough to allow the range to be pulled out for service.
3.
Slide the gas line up through the access holes in the chassis
and up to the regulator. Move the wires around inside the
access holes to prevent them from catching on the gas line
as you push it up.
4.
Connect the gas line to the regulator.
5.
Turn all cooktop
control valves to the
OFF position.
OFF Icon
6.
Turn on the gas
supply and check all
lines and connections
for leaks using a soap
and water solution.
7.
Turn the gas shut-
off valve to the OFF
position.
WARNING
Regulator
connection
Access
holes
Back of range
Gas
line
17