Document # PG05-003
46 1/4" (1175 mm)
1 9/16"
(40 mm)
Width at front panel:
29 7/8" (758 mm)
fREEStANDING moDELS ER30D AND ER30D-C
NOTE: Models ER30D and ER30D-C are NOT designed for
use with self-rimming installations or raised vents. Use model
ER30DSR for self-rimming and raised vent installations.
1 9/16"
(40 mm)
Width at front panel:
29 7/8" (758 mm)
SELf RImmING moDEL ER30DSR
SIDE DImENSIoNS
wIth oPtIoNAL RAISED VENt
tRIm kIt INStALLED (Atk30SR)
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
ER30D, ER30DSR
Epicure
28 13/16" (732 mm)
27 5/16" (694 mm)
26 5/16" (668 mm)
24 1/4" (616 mm)
1 1/16" (27 mm)
9" (229 mm)
Backguard**
3" (76 mm)
Backguard*
1 1/16" (27 mm) to cooking
surface (top of grates) from
top of trim
35 3/4"
(908 mm)
Finished side panel
37 7/8"
(962 mm)
46 1/8" (1172 mm)
Front of open door
28 11/16" (729 mm)
Front of handle
27 3/16" (691 mm)
Front edge of bullnose
26 3/16" (665 mm)
Front panel
Rear of front panel /oven door
24 1/8" (613 mm)
23 1/8" (587 mm)
Rear of front panel to
back of chassis
1 5/16" (33 mm) to cooking
surface (top of grates) from
bottom of trim
35 3/4"
(908 mm)
to
37 7/8"
(962 mm)
Ranges
®
Product tolerances: ±1/16" (±1.6 mm) unless otherwise stated
NOTE:
6" (152 mm)
Backguard**
*
Standard
** Optional
to
1 9/16"
(40 mm)
Width at front panel:
29 7/8" (758 mm)
Range Model
ER30D/ER30DSR
* 4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground
www.Dacor.com
PLANNING
waRNINg
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
This appliance must be installed in accordance with
the accompanying installation instructions.
Self-rimming models are designed to allow the trim to
overlap the countertop when configured to the dimensions
on page 1/3.
Self-rimming models are not compatible with integral
backguards
45 5/8" (1159 mm)
28 3/16" (716 mm)
26 11/16" (678 mm)
25 11/16" (652 mm)
23 5/8" (600 mm)
23 1/8" (587 mm)
1 5/16" (33 mm) to cooking
surface (top of grates) from
bottom of trim
SELf RImmING moDEL ER30DSR
SIDE DImENSIoNS
wIth StANDARD tRIm
ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required
240 Vac, 4-wire*
60 Hz, 30 Amp.
The ratings above are for reference only -
refer to the range rating label
Phone: (800) 793-0093
Revised 08/23/10 Page 1/3
GUIDE
Front of open door
Front of handle
Front edge of bullnose
Front panel
Rear of front panel /oven door
Rear of front panel to
back of chassis
35 3/4"
(908 mm)
to
37 7/8"
(962 mm)
Total Connected
Load
5.6 kW (24.2 Amp.)
5.7

Advertisement

loading

Summary of Contents for Dacor Epicure ER30D

  • Page 1 The ratings above are for reference only - refer to the range rating label SELf RImmING moDEL ER30DSR SIDE DImENSIoNS wIth oPtIoNAL RAISED VENt tRIm kIt INStALLED (Atk30SR) Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.Dacor.com Phone: (800) 793-0093...
  • Page 2 Consult local code for exact location requirements. Not applicable for cabinets more than a horizontal distance of 10” (254 mm) from the edge of the range. Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.Dacor.com Phone: (800) 793-0093...
  • Page 3 ** IMPORTANT: If optional 3-inch side panels are not installed cabinet face must be flush with back of control panel. Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.Dacor.com Phone: (800) 793-0093...

This manual is also suitable for:

Er30dsr