Dacor Epicure ER30DSCH Installation Instructions Manual
Dacor Epicure ER30DSCH Installation Instructions Manual

Dacor Epicure ER30DSCH Installation Instructions Manual

Dacor epicure er30dsch: install guide
Hide thumbs Also See for Epicure ER30DSCH:

Advertisement

Part No. 102187 Rev. G
Epicure
Range
®
For Use with Models: ER30D, ER30D-C, ER30DSR
THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF
ANSI Z21.1 STANDARD FOR HOUSEHOLD GAS APPLIANCES.

Installation Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Epicure ER30DSCH and is the answer not in the manual?

Questions and answers

Summary of Contents for Dacor Epicure ER30DSCH

  • Page 1: Installation Instructions

    Epicure For Use with Models: ER30D, ER30D-C, ER30DSR THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21.1 STANDARD FOR HOUSEHOLD GAS APPLIANCES. Part No. 102187 Rev. G Installation Instructions Range ®...
  • Page 2 All specifications subject to change without notice. Dacor ® assumes no liability for changes to specifications. © 2007 Dacor, all rights reserved.
  • Page 3: Table Of Contents

    Use common sense and caution when installing, maintaining or operating this or any other appliance. Always contact the Dacor Customer Service Team about problems and conditions that you do not understand. Safety Symbols in this Manual...
  • Page 4: Important Safety Instructions

    Do not leave children or pets alone or unattended in the area around the range. Do not allow children to play with the controls, pull on the handle, or touch other parts of the range. • Do not store items of interest to children on top of or above the range. Children could be burned or injured while climbing on the appliance. •...
  • Page 5: Customer Service Information

    Customer Service Information If you have questions or problems with installation, contact your Dacor dealer or the Dacor Customer Service Team. For repairs to Dacor appliances under warranty call the Dacor Distinctive Service line. Whenever you call, have the model and serial number of the appliance ready.
  • Page 6: Warning

    (natural gas or LP gas). Also, if operating the range at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation. Refer to the range rating label and the table on page 3 to determine the correct model. •...
  • Page 7: Product Dimensions

    21 3/4” (124 mm) (552 mm) * When using an appliance cord, the hole size must be increased to 1 1/8” by removing the conduit bracket inside the range electrical access box. 46 1/4” (1175mm) 28 13/16” (732mm) 27 5/16” (694mm) 26 5/16”...
  • Page 8 Planning the Installation Product Dimensions (continued) All tolerances: ±1/16” (±1.6 mm) unless otherwise stated 1 9/16” (40mm) Width at front panel: 29 7/8” (758mm) 1 9/16” (40mm) Width at front panel: 29 7/8” (758mm) with Optional Raised Vent Trim Kit (ATK30SR) Installed NOTE: Self-rimming models are designed to allow the trim to over- lap the countertop when configured to the dimensions on page 8.
  • Page 9: Warning

    • In freestanding configuration, the range may be installed flush to the rear wall. For all installations, Dacor highly recommends installing a non-combustible material on the rear wall above the range and up to the vent hood or installation of a backguard.
  • Page 10: Warning

    • On installations with a raised vent (see above right), install Dacor trim kit ATK30SR. When sliding the range into position, it stops when the rear of the control panel contacts the notches toward the countertop front. The range trim will partially cover the front of the raised vent chassis in the back.
  • Page 11: Backguard Installation

    For self-rimming installations with non-standard countertop depths, installation of the optional side panel kit may be necessary to cover the sides of the range that protrude from the cabinet. To install the side panel kit: Open the oven door. Remove and retain the two (2) screws on the top of the kick panel.
  • Page 12 End Cap Hold the left side panel in position on the side of the range. Locate the center mounting hole. Remove and retain the screw attached to the chassis beneath it.
  • Page 13: Level And Adjust The Range Height

    65335. IMPORTANT: The ERV30 or PRV30 raised vent attaches to the narrow back portion of the raised vent/range cutout. It is self- supporting in the cutout and does not actually attach to the range itself. Installation Instructions Level and Adjust the Range Height Raise or lower the range to prepare for final installation: ◊...
  • Page 14: Removing The Oven Door

    Verify Proper Operation section of these instructions. • Improper connection of the electrical wiring can cause an electric shock hazard and damage the appliance. Dacor is not responsible for damages resulting from improper installation. • The ground terminal (or lead) on the appliance must be connected to a grounded, metallic, permanent wiring system or grounding conductor.
  • Page 15 Installation Instructions Installation Instructions Connecting the Wiring to the Range Refer to the range rating label (see page 3) for power requirements. There are four possible ways to wire the range: • 4 Wire Conduit • 3 Wire Conduit (where local codes permit) •...
  • Page 16: Wire Connection Conduit

    Do not ground the appliance to a gas supply pipe or hot water pipe. • Do not turn on power to the appliance until the range is permanently grounded. • A grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by insulating materials.
  • Page 17 Installation Instructions Junction Connection to power supply Wire Nut, 4 Places Connection to appliance (Page 13) 4 Wire Connection Conduit Junction Box Connection with External Ground No. 4 copper wire Metal Water Pipe Insulated Pipe Jumper Separate No. 10 (minimum copper grounding wire Fasten clamp tightly on pipe...
  • Page 18 Do not connect the green appliance wire to the neutral (white) supply wire unless local building codes permit. Remove the range electrical access cover from the back of the range. If using a 4 wire connection, loosen the grounding screw and remove the neutral to ground jumper link.
  • Page 19: Gas Supply Connection

    Gas Supply Connection • Make sure the gas supply valve is off and that the power to the range is turned off at the circuit breaker or fuse box prior to connecting the gas line. • Do not apply excessive pressure when tightening gas connections and fittings.
  • Page 20: Final Installation

    Use a level to make sure that the range does not tilt front to back or side to side. Readjust the legs if necessary.
  • Page 21: Installing The Burner Components

    Installing the Burner Components WARNING Never attempt to operate the cooktop section of the range with any of the burner rings, burner caps or grates removed. • Remove the burner rings, burner caps and grates from their shipping packages. •...
  • Page 22: Verifying Proper Operation

    Repeat the above bake test or burner ignition test. If the appliance still does not work, contact Dacor Distinctive Service at (877) 337-3226. Do not attempt to repair the appliance yourself. If you need service, be sure to have the model and serial numbers available when you call.
  • Page 24 Dacor ● 1440 Bridge Gate Drive, Diamond Bar, CA 91765 ● Tel: (800) 793-0093 ● FAX: (626) 403-3130 ● www.Dacor.com...

This manual is also suitable for:

Epicure er30dsrschEr30dEr30dsrEr30d-c

Table of Contents