46 1/4" (1175mm)
28 13/16" (732mm)
27 5/16" (694mm)
26 3/8" (670mm)
24 1/4" (616mm)
Finished Side
E
r
lEctrical
EquirEmEnts
It is the owner's responsibility to ensure that the electrical
connection of this appliance is performed by a qualified electrician.
The electrical installation, including minimum supply wire size
and grounding, must be in accordance with the National Electric
code ANSI/NFPA 70-1993* (or latest revision) and local codes and
ordinances. A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency, and amperage must be
supplied to the appliance from a separate, grounded, circuit
that is protected by a properly sized circuit breaker or time
delay fuse. Refer to the chart below for requirements.
A 4-wire connection (not provided) is required to connect the
range to the junction box. The minimum wire gauge suggested
by Dacor
is 10 AWG. Consult local building codes for the
®
type and minimum wire gauge to use.
Suggested wiring color code: Black, white, red, and green.
The wiring needs to be long enough to allow the range to be pulled
out from the wall for service, while remaining connected.
ELECTRIC CIRCUIT REQUIREMENTS
Range Model
Circuit Required
ER30D
60Hz, 30A
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Epicure™ Ranges
071707
1 1/16" (27mm)
6" (152mm)
Backguard
3" (76mm)
Backguard
37 1/2"
(953mm)
Panel
to
35 3/8"
(899mm)
Total Connected
Load
240VAC,
5.6kW (23A)
ER30D
G
s
as
upply
Check your local building codes for the proper method of
installation. In the absence of local codes, this appliance
should be installed in accordance with the National Fuel Gas
Code ANSI Z223.1.
Be certain that the appliance being installed is correct for the
gas service being provided (natural gas or LP gas). Also, if
operating the range at an altitude above 4000 ft. (1219 m)
make sure it is equipped for high altitude operation. Refer to
the range data plate and the table on page 3 to determine the
correct model.
See the table below for gas supply pressure requirements.
The regulator inlet accommodates a 3/4" gas line. The range
ships with a 1/2" to 3/4" adapter connected to the regulator.
GAS SUPPLY PRESSURE REQUIREMENTS
Gas Type
Natural Gas
Liquid Petroleum
(LP)
B
D
A
GAS - ELECTRICAL ACCESS DIMENSIONS
"A"
4 7/8"
Specifications are subject to change without notice.
See installation instructions for additional details.
PLANNING
1/2
r
EquirEmEnts
Manifold Pressure
5" Water Column
10" Water Column
Gas Inlet
Range Electrical Access,
Cover Removed
E Conduit Connection
C
Hole in Bottom
Back of Range
"B"
"C"
21 3/4"
9 1/16"
GUIDE
Minimum Gas
Supply Pressure
6" Water Column
11" Water Column
"D"
"E"
10 1/2"
7/8"
5.10

Advertisement

loading
Need help?

Need help?

Do you have a question about the Epicure ER30D and is the answer not in the manual?

Questions and answers

Summary of Contents for Dacor Epicure ER30D

  • Page 1 ◊ A 4-wire connection (not provided) is required to connect the range to the junction box. The minimum wire gauge suggested by Dacor is 10 AWG. Consult local building codes for the ® type and minimum wire gauge to use.
  • Page 2 The range may be installed flush to the rear wall. Dacor recommends installing a non-combustible material on the rear wall above the range and up to the vent hood. If a non- combustible surface is not installed, a backguard must be installed. It is not necessary to install non-combustible materials behind the range below the countertop height.