Epicure ® Range
For use with models ER3OD, ER3OD-C, ER3ODSR
Installation
Instructions
THIS APPLIANCE
HAS BEEN TESTED IN ACCORDANCE
WITH THE LATEST EDITION
OF ANSI Z21.1 STANDARD
FOR HOUSEHOLD
GAS COOKING APPLIANCES.
Part No. 102187
Rev. J

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ER3OD and is the answer not in the manual?

Questions and answers

Summary of Contents for Dacor ER3OD

  • Page 1 Installation Instructions Epicure ® Range For use with models ER3OD, ER3OD-C, ER3ODSR THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21.1 STANDARD FOR HOUSEHOLD GAS COOKING APPLIANCES. Part No. 102187 Rev. J...
  • Page 2 All specifications subject to change without notice. Dacor ® assumes no liability for changes to specifications. © 2007 Dacor, all rights reserved.
  • Page 3: Table Of Contents

    Always contact the Dacor Customer Service Team about problems • From a neighbors phone, immediately call the gas supplier and conditions that you do not understand...
  • Page 4 General Safety Precautions To reduce the risk of fire, explosion, electric shock, serious injury or death when installing or using this appliance, follow basic safety _recautions, including the following: Read the accompanying use and care manual completely before operating this appliance. •...
  • Page 5: Customer Service Information

    Ifyouhave questions orproblems withinstallation, contact your Model Identification Dacor dealer ortheDacor C ustomer Service Team. Forrepairs toDacor a ppliances under w arranty, call t heDacor D istinctive E R30 DS R-C-SC H/N G/H TT --- Service line. W henever youcall, h ave themodel andserial number oftheappliance ready.
  • Page 6: Planning The Installation

    Electrical Requirements Freestanding Units for Use in Canada • It is the owner's responsibility to ensure that the required 4 wire electrical outlet is installed by a licensed electrician Electrical Requirements as specified below prior to range installation The electrical outlet installation, including minimum supply wire size and IMPORTANT: The information below applies only to freestanding grounding, must be in accordance with all governing codes...
  • Page 7: Product Dimensions

    Product Dimensions Product tolerances: +1/16" (+1.6 mm), unless otherwise stated l\Gas GAS - ELECTRICAL ACCESS DIMENSIONS _' inlet Range electrical access, 4 7/8" 21 3/4" 8 5/8" 10 3/16" , ,_ cover removed (124 mm) (552 mm) (219 mm) (259 mm) * When using an appliance cord, the hole size must be increased to 1 1/8"...
  • Page 8 +1/16" (+1.6 mm), unless otherwise stated page 8. NOTE: Self-rimming models are not compatible with Dacor integral backguards. 45 5/8" (1159 mm) Front of open door Front of handle 28 3/16" (716 mm) 11/16" (678 mm)-_ Front edge of bullnose 11/16"...
  • Page 9: Cabinet Layout

    • In the freestanding configuration, the range may be installed the range is in place. flush to the rear walt. For all installations, Dacor highly • The gas supply piping, gas shut-off valve and the electrical recommends installing a non-combustible...
  • Page 10: Installation Instructions

    Cabinet Layout (continued) APPROVED RAISED VENT MODELS: Use onlv Dacor model ERV30 or PRV30. 10" Min. -.. 3/8" Min. (10 mm) 10" Min.\ 1/4" Min. (6 mm) Non-combustible (254 mm) "_ Countertop Non-combustible rear wall recommended (254 mm) _ Countertop...
  • Page 11 Backguard (models ER30D Installing the ATK3OSR Raised Vent Trim (model ER3ODSRonly) and ER3OD-C only) Models ER30D and ER30D-C come standard with a 3" backguard To install the optional raised vent with self-rimming model installed• The 6" and 9" backguards are optional•...
  • Page 12 Insert the tabs on the trim piece into the slots on the range. ARSP3 Side Panel Kit Installation (cont.) Use the hex head screw (83023) removed from the side, a Close the door. Remove and retain the two screws from the Torx head screw removed from the kick panel and the hex back of the kick panel as shown below.
  • Page 13 With the door closed, reattach the kick panel to the range Level and Adjust the Range Height by snapping the ball studs on the back of the panel into the Raise or lower the range to prepare for final installation: holes on the front panel of the range.
  • Page 14: Electrical Connection

    Electrical Connection Removing the Oven Door To make the range easier to move, remove the door to reduce weight. Open the door to its fully opened position. Rotate the catch over the retaining arm on each hinge. NOTE: Freestanding model ER30D-C is wired for use in Canada and comes from the factory pre-wired.
  • Page 15 Connecting the Wiring to the Range Refer to the range rating label (see page 3) for power requirements. L1 terminal There are four possible ways to wire the range: Neutral terminal _ • 4 wire conduit • 3 wire conduit (where local codes permit) Jumper link •...
  • Page 16 Electrical Connection (Continued) Connecting the Conduit to the House Connection to Electrical Junction Box power supply Junction box Wire nut 3 places .WHITE [_RED •WHITE BLACK _ BLACK IMPORTANT: The power supply must be properly polarized• Reverse polarity wilt result in continuous sparking of the electrodes, even after flame ignition•...
  • Page 17 Separate No. 10 (minimum) Connection to power supply copper grounding wire Junction box Wire nut 4 places Connection to appliance (Page 13) 4 Wire Conduit Connection to Junction Box with External Ground No. 4 Meter copper wire Metal water pipe Clamps Bare metal...
  • Page 18 Slide the end of the appliance cord into the strain relief from Electrical Connection (Continued) the bottom of the box. Appliance Cord Connections - Where Connect the white (neutral) wire to the neutral terminal in the box. Local Code Permits Connect the L1 wire to the L1 power supply terminal in the box.
  • Page 19: Gas Connection

    Gas Connection Bare wire connections Loop and spade terminal connections L1 terminal Neutral terminal L2 terminal Link removed Ground screw _ --_ (_ L2 wire NOTE: The gas pressure regulator is pre-set at the factory for the type of gas intended for use with the appliance. To verify that Green wire the appliance is compatible with the type of gas available, check the range rating label (see page 3 for location).
  • Page 20: Final Installation

    Final Installation Installing the Burner Knobs Peel the protective plastic coating off of the range, including the range door. Carefully slide the range into position in the cutout. The rear anti-tip leg should engage the anti-tip bracket. On self-rimming installations, reach under the range and There are two (2) different types of knobs supplied with the range.
  • Page 21: Cooktop Assembly

    Cooktop Assembly Spilt tray Remove the burner rings, burner caps and grates from their shipping packages. Stack burner • Install the burners as shown. Crown burner • Gently set the grates on top of the spill tray. Put the legs of each grate inside the corresponding dimples.
  • Page 22: Verifying Proper Operation

    Repeat the above bake test or burner ignition test. If the appliance still does not work, contact Dacor Distinctive Service at (877) 337-3226. Do not attempt to repair the appliance yourself. Have the model and serial numbers available when you call.