Installation Instructions; Preparing For Installation - Dacor Epicure ER30D Installation Instructions Manual

Installation instructions
Hide thumbs Also See for Epicure ER30D:
Table of Contents

Advertisement

Cabinet Layout (continued)
Non-combustible
rear wall recommeded
Combustible side
wall above range
29 1/2" (749 mm)
countertop opening
30" (762 mm)
cabinet opening
below countertop
Cabinet face
below countertop
Notch countertop
overhang to width of
cabinets
Countertop Height: Min: 35 5/8" (905 mm) Max: 37 3/8" (949 mm)
Top View - Model ER30DSR - Counter/Cabinet Cutout
Dimensions for Self-Rimming Installation
Notes For All Self-Rimming Installations:
On installations without a raised vent (see above), when
sliding the range into position, it will stop when the rear of
the control panel contacts the notches toward the front of the
countertop. The range trim will partially cover the overhang in
back.
On installations with a raised vent (see above right), install
Dacor trim kit ATK30SR. When sliding the range into position,
it will stop when the rear of the control panel contacts the
notches toward the front of the countertop. The range trim will
partially cover the front of the raised vent chassis in back.

Preparing for Installation

If the gas or electric service provided does not meet the
product specifications, do not proceed with the installation.
Call the dealer, the gas supplier or a licensed electrician.
Before installing the range, you must locate and secure the
anti-tip bracket to the floor.
Be sure that the unit is not connected to gas or power
before proceeding with the following sections.
IMPORTANT: Within the Commonwealth of Massachusetts, this
appliance must be installed by a licensed plumber or gas fitter.
NOTE: When installing a backguard, always install it before
sliding the range into place. See page 9.
Unpacking the Range
Unpack the range and verify that all required parts have been
provided. If any item is missing or damaged, please contact
your dealer immediately. Do not install a damaged or incomplete
appliance. The customer must report cosmetic issues within 30
days of installation.
8
Planning the Installation
10" Min.
1/4" Min. (6 mm)
(254 mm)
Countertop
both sides
overhang
H J K
Countertop front

Installation Instructions

WARNING
APPROVED RAISED VENT MODELS: Use only Dacor model
ERV30 or PRV30.
Non-combustible
rear wall recommended
27 1/2" (699 mm)
raised vent opening
29 1/2" (749 mm)
countertop opening
30" (762 mm)
cabinet opening
below countertop
Combustible side
wall above range
Cabinet face
below countertop
Notch countertop
overhang to width of
cabinets
Countertop Height: Min: 35 5/8" (905 mm) Max: 37 1/4" (946 mm)
Top View - Model ER30DSR - Counter/Cabinet Cutout
Dimensions - Self-Rimming Installation with Raised Vent
ER30DSR with
no side panels no
raised vent
(597 mm)
3-inch side panels*
and no raised vent
(521 mm)
no side panels and
raised vent
(610 mm)
3-inch side panels
and raised vent
(533 mm)
* Optional side panels (PN ARSP3) cover unfinished chassis sides
when the cabinet face is recessed behind back of control panel.
Parts List
2 grates
1 small stack burner cap
1 small stack burner ring
2 large stack burner caps
2 large stack burner rings
1 crown burner cap
1 crown burner ring
1 crown burner head
1 GlideRack™ oven rack
See the use and care manual for a list of optional accessories.
3/8" Min. (10 mm)
10" Min.
Countertop
(254 mm)
overhang
both sides
2 3/8" (60 mm)
H J K
Countertop front
H
J
23 1/2"
23 1/2"
(597 mm)
20 1/2"
20 1/2" to
23 1/2"
24"
24"
(610 mm)
21"
21" to 24"
2 standard size racks
4 knobs
Anti-tip bracket w/screws
Meat probe
Griddle
Wok ring
Stainless steel cleaner
Literature kit
Broiler pan/grill
K
24" to
25 9/16"
21" to
25 9/16"
24 1/2" to
26 1/16"
21 1/2" to
26 1/16"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Er30dsrEr30d-c

Table of Contents