Lexicon, Inc.
MC-8 Serial Communications Protocol
6.3.25 MC-8 Set Parameter Value by Id, No Run
MC-8 Set Parameter by Id command sets the parameter value equal to the value sent in the command packet and
does not run the appropriate functional changes associated with changing the given parameter.
6.3.25.1 Command Packet Description
Application Header:
Command
Data Count 24
Application Data:
Data[0]
Data[1]
Data[2]
Data[3-23]
6.3.25.2 Data Description
Same as
Paragraph 6.3.24.2
6.3.26 MC-8 Get Unit Configuration
Request to MC-8 for its current unit configuration. MC-8 will respond with "Unit Configuration Packet". The
HOST should use this information to determine if any information saved by the HOST is current.
6.3.26.1 Command Packet Description
Application Header:
Command
Data Count
Application Data:
© 2003 Lexicon, Inc. All rights reserved.
MC_CMD_SET_SYS_PARAM_VALUE_BY_ID_NO_RUN 0x37
ParamId(LSB)
ParamId(MSB)
ParamType
Value[0 -20]
MC_CMD_GET_CONFIG
0
N/A
Printed on: 04/01/03
0x18
nn
nn
nn
nn nn
nn...
0x38
0x00
34 of 80