Set Main Balance - Lexicon MC-8 V1.0 - SERIAL COMMUNICATIONS PROTOCOL DEFINITION REV 1-4 Manual

Serial communications protocol
Table of Contents

Advertisement

Lexicon, Inc.
MC-8 Serial Communications Protocol
6.3.9.1 Command Packet Description
6.3.9.2 Data Description
Value:
Data Type:
Max:
Conversion:
6.3.9.3 MC-8 Response
The MC-8 will assign the value from the packet to the system volume.
6.3.9.4 Data Validation
If a value is passed that exceeds the maximum value of that parameter the MC-8 will ignore the command and
transmit a DC_NAK command with an error code DC_INVALID_DATA.

6.3.10 Set Main Balance

Commands MC-8 to set the system balance to the value in this packet.
This command has been maintained for backward compatibility with MC-1. In order to maintain backward
compatibility, the MC-8 Parameters have been mapped to the MC-1 parameters as described in each Data
Description. MC-8 users should be using the command described in
6.3.10.1 Command Packet Description
Application Header:
Command
Data Count 1
Application Data:
Data[0]
6.3.10.2 Data Description
Value:
Data Type:
Maximum Value: 32
Conversion:
6.3.10.3 MC-8 Response
The MC-8 will assign the value from the packet to the system balance.
© 2003 Lexicon, Inc. All rights reserved.
Application Header:
Command DC_CMD_SET_SYS_VOLUME
Data Count 1
Application Data:
Data[0]
Value
Unsigned 8 bit integer.
92
0 = -80 dB
92 = +12 dB
DC_CMD_SET_SYS_BALANCE
Value
Unsigned 8 bit integer.
0 = Left
16 = Center
32 = Right
Printed on: 04/01/03
0x21
0x01
nn
6.3.35
(MC8_Set_Main_Balance).
0x22
0x01
nn
22 of 80