6.3.6 Get Zone 2 Status
This command is a request to MC-8 for current Zone 2 Status. MC-8 will respond with "Zone2 Status Packet".
This command has been maintained for backward compatibility with MC-1. In order to maintain backward
compatibility, the MC-8 Parameters have been mapped to the MC-1 parameters as described in each Data
Description. MC-8 users should be using the command described in
6.3.6.1 Command Packet Description
Application Header:
Command DC_CMD_GET_ZONE2_STATUS 0x17
Data Count 0
Application Data:
6.3.6.2 Zone2 Status Response Packet
Application Header:
Command DC_RESP_ZONE2_STATUS
Data Count 5
Application Data:
Data[0]
Data[1]
Data[2]
Data[3]
Data[4]
6.3.6.3 Data Description
Zone2 Volume:
Data Type:
Maximum Value: 92
Conversion:
Assigned Zone 2 Input:
Indicates the Zone 2 input that is currently assigned for the zone 2 outputs.
Data Type:
Definition/Conversion:
© 2003 Lexicon, Inc. All rights reserved.
0 = Front
16 = Center
32 = Back
Boolean.
MC-8 has detected Video Sync for current video input
MC-8 can not detect Video Sync for the current video input
N/A
Zone2 Volume
Assigned Zone 2 Input
Zone2 Mute Active
Reserved for Future Use
Zone2 Balance
Unsigned 8 bit integer.
0 = -80 dB
92 = +12 dB
Unsigned 8 bit integer.
Appendix F MC-8 Input Ids
Printed on: 04/01/03
6.3.33
(MC8_Get_Zone_2_Status).
0x00
0x82
0x05
nn
nn
nn
nn
nn