Mc-4 Set Parameter Value By Id, No Run; Mc-4 Get Unit Configuration - Lexicon MC-4 V1.00 - SERIAL PROTOCOL DEFINITIONS REV 1-6 Manual

Serial protocol definitions
Table of Contents

Advertisement

Lexicon

6.3.13 MC-4 Set Parameter Value by Id, No Run

MC-4 Set Parameter by Id command sets the parameter value equal to the value sent in the command
packet and does not run the appropriate functional changes associated with changing the given
parameter.
6.3.13.1 Command Packet Description
Application Header:
Command
Data Count 24
Application Data:
Data[0]
Data[1]
Data[2]
Data[3-23]
6.3.13.2 Data Description
Same as MC-4 Set Parameter Value by Id: Data Description

6.3.14 MC-4 Get Unit Configuration

Request to MC-4 for its current unit configuration. MC-4 will respond with "Unit Configuration Packet".
The HOST should use this information to determine if any information saved by the HOST is current.
6.3.14.1 Command Packet Description
Application Header:
Command
Data Count
Application Data:
MC_CMD_SET_SYS_PARAM_VALUE_BY_ID_NO_RUN
ParamId(LSB)
ParamId(MSB)
ParamType
Value[0 -20]
MC_CMD_GET_CONFIG
0
N/A
MC-4 Serial Communications Protocol
0x37
0x18
nn
nn
nn
nn nn nn...
(6.3.12.2 page
20).
0x38
0x00
21