4.6 Troubleshooting
The table below offers troubleshooting guidance for common device installation issues. If your problem isn't resolved
by the steps outlined, please contact your dealer for additional support.
Symptom
None of the LEDs on the router
are lighting up.
The local console is unrespons-
ive.
The local console is displaying
irrelevant information.
Forgotten router access pass-
word.
The device loses date and time
settings upon restarting.
The LAN1, LAN2, or SFP/LAN3
LEDs are not lighting up green.
The S LED is red.
4.7 Updating the Software
The Regesta Smart v2 Nessum router supports updating to the latest software releases. For detailed information
about available updates, we recommend contacting your distributor.
There are several methods for updating our routers. For step-by-step guidance, please refer to the "Teldat Dm 748-I
Software Updating" manual.
The required software is provided in a distribution format, consisting of a single file that contains all necessary update
components, along with detailed information about their contents.
Regesta Smart v2 Nessum
Solution
Check the router's power supply, including the power source and main power out-
let.
Confirm that the correct console cable is being used and properly connected to
both the device and asynchronous terminal.
Ensure the terminal is set to the correct port.
Verify that the terminal settings are 115200 8N1.
Ensure the console isn't being used for event processing.
Confirm that the terminal is set to the correct port.
Verify that the terminal settings are 115200 8N1.
Reset the configuration using the RST button (refer to the relevant section for in-
structions).
Any settings configured via the time set command are not saved after a restart.
Use the NTP protocol to maintain accurate date and time settings.
Check the Ethernet cable, fiber connection, and network setup (a crossover cable
may be needed).
For further guidance, consult the "Teldat Dm709-I LAN Interfaces" manual.
Ensure the SIM card is properly inserted.
Verify that the SIM PIN is correct.
Check that the antenna is correctly installed and securely screwed in.
Have technical support confirm that the device is optimally positioned for service.
For more details, refer to the "Teldat Dm781-I Cellular Interface " manual.