5002
PM ON EM (FILTER, WARNING SYSTEM
&
BATTERY)
• 3-2
*
*
THE FOLLOWING PM TASKS SHOULD BE DONE IN CONJUNCTION WITH AN
*
UNSCHEDULED EM TRIP ON THE SITE OR A SCHEDULED MEMORY MAINT-
*
ENANCE TRIP, REFER TO CAMS ID Cl80810 TASK 5001.
*
*
AIR FILTER CHECK/CLEAN
**************************
*
*
THERE ARE THREE AIR FILTERS IN THE 810/830 CABINETS.
ONE
*
LOCATED IN THE FRONT DOOR OF THE POWER CABINET, AND ONE UNDER
*
EACH OF THE LOGIC COLUMNS IN THE FRONT OF THE LOGIC CABINET.
*
*
*
CLEAN AS REQUIRED.
*
WARNING SYSTEM CHECK
************************
*
*
*
*
*
ANY SITUATION REQUIRING A POWERING DOWN OF THE UNIT CAN
BE USED AS AN OPPORTUNITY TO TEST THE WARNING SYSTEM.
THIS MUST BE DONE AT LEAST ONCE EACH YEAR.
*
1.
PRESS THE CABINET POWER OFF BUTTON.
*
*
2.
PRESS AND HOLD THE AIR FLOW SENSOR TEST PUSHBUTTON
*
SWITCH FOR TWO TO THREE MINUTES UNTIL THE LOW AIR
*
FLOW AND FAULT INDICATORS LIGHT.
HOLD THE SWITCH IN
*
FOR AN ADDITIONAL TWO MINUTES AND THE CIRCUIT BREAKERS
*
WILL TRIP.
*
*
3.
TO POWER THE UNIT BACK UP, RESET THE CIRCUIT
*
BREAKERS. PRESS THE RESET SWITCH AND THE ON
*
SWITCH.
*
*
*
BATTERY OPTION CHECK
*************************
60469500
c