TABLE A-8.
ERROR STOPS FOR lX INSTRUCTIONS (Page 2 of 2)
p
Rgtr
Q
Rgtr
K
Rgrt
A Rgrt
Suspected Failing Module(s)
6447
6446
0500
xx xx xx
CR, CP
6474
6473
0500
xxxxxx
CR, CP
6506
6505
0400
xxxxxx
CR, CP
6510
6507
0500
xxxxxx
CR, CP
TABLE A-9.
ERROR STOPS FOR 3X INSTRUCTIONS
p Rgtr
Q
Rgtr
K Rgrt
A Rgrt
Suspected Failing Module(s)
6511
6510
3400
xxxxxx
CP, CR
6516
6515
3000
xxxxxx
CP, CR
6517
6516
0500
xxxxxx
CM, CR
6521
6520
0400
xxxxxx
CM, CR
6522
6521
3100
xxxxxx
CP, CR
6525
6524
0500
xxxxxx
CM, CR
6527
6526
3200
xxxxxx
CP, CR
6531
6530
0500
xxxxxx
CM, CR
6533
6532
3300
xxxxxx
CP, CR
6535
6534
0500
xxxxxx
CM; CR
6537
6536
3500
xxxxxx
CP, CR
6541
6540
0500
xxxxxx
CM, CR
6552
6551
0500
xxxxxx
CM, CR
6553
6552
3600
xxxxxx
CP, CR
6554
6553
3700
xxxxxx
CP, CR
TABLE A-10.
ERROR STOPS FOR 4X INSTRUCTIONS
p
Rgtr
Q
Rgtr
K
Rgrt
A Rgrt
Suspected Failing Module(s)
6563
6562
4400
xxxxxx
CP, CR
6566
6565
4000
xxxxxx
CP, CR
6570
6567
0500
xxxxxx
CR, CM
6572
6571
4100
xxxxxx
CP, CR
6573
6572
0500
xxxxxx
CR, CM
6574
6573
4200
xxxxxx
CP, CR
6576
6575
0500
xxxxxx
CR, CM
6577
6576
4300
xxxxxx
CP, CR
6601
6600
0500
xxxxxx
CR, CM
6602
6601
4600
xxxxxx
CP, CR
6606
6606
0300
xxxxxx
CR, CM
6611
6610
4700
xxxxxx
CP, CR
6614
6613
0500
xxxxxx
CR, CM
6616
6615
4500
xxxxxx
CP, CR
6624
6623
0500
xxxxxx
CR, CM
60469500 A
A--9