PD27/28/29/30 INSTALLATION INSTRUCTIONS
SVR DEVICE
2. SIZE DEVICE
 Standard lengths are for 36" or 48" door.
Device must be cut for other lengths.
 Mark length with tape – length equals
desired door size subtracted from device
size (for 30" door = cut 6" off 36" device)
ensuring a square cut.
1. PREPARE DOOR
 Prepare door, frame and floor or
 Refer to trim template if installing trim.
36" Device
48" Device
3. INSTALL DEVICE
 Install device and trim with chassis/case
 Device can be surface mounted to the
 VF devices must be through bolted on
Reinforced Steel
Surface Mount: Drill/Tap push side for 1/4-20
or Aluminum Door
Solid Wood Door Drill 1/8" Pilot Hole for #10 Wood Screw
All Others
Use optional Sex Bolts. Drill push side with
9/32" drill bit. Drill pull side with 3/8" drill bit.
1
888-622-2377 | commandaccess.com
threshold according to template.
Maximum cut off length:
Panic Fire Alarm MLR
6"
8"
12"
14"
screws (2 or 4 screws depending on
device and trim type).
door, optional sex nuts are available,
device is through bolted if using trim.
wood or composite doors.
Mounting Options:
2"
3"
8"
9"
20684_A (639401 Rev1)

Advertisement

loading
Need help?

Need help?

Do you have a question about the PD29 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Command access PD29

  • Page 1 PD27/28/29/30 INSTALLATION INSTRUCTIONS SVR DEVICE 888-622-2377 | commandaccess.com 1. PREPARE DOOR  Prepare door, frame and floor or threshold according to template.  Refer to trim template if installing trim. 2. SIZE DEVICE  Standard lengths are for 36" or 48" door. Device must be cut for other lengths.
  • Page 2 PD27/28/29/30 INSTALLATION INSTRUCTIONS SVR DEVICE 4. INSTALL END CAP  Slide end cap into rail. Ensure rail is level. Mark the slots.  Remove end cap and prepare holes using the chart from Step 3.  Reinstall end cap and fasten with screws. PIN IN ...
  • Page 3 PD27/28/29/30 INSTALLATION INSTRUCTIONS SVR DEVICE 7. ADJUST TOP ROD  Ensure top latch is in the unlatched position by lifting up then releasing the rod. Rod should remain up.  Depress the push bar and adjust the top rod connector by threading it in or out of the rod until it lines up with the screw hole in the device head.
  • Page 4 PD27/28/29/30 INSTALLATION INSTRUCTIONS SVR DEVICE 10. ADJUST BOTTOM ROD *Omit this step for LBR devices.  Ensure top latch is in the unlatched position.  While the top latch is in the unlatched position adjust the bottom rod until it clears the strike by approximately 1/8".
  • Page 5 PD27/28/29/30 INSTALLATION INSTRUCTIONS SVR DEVICE CUT TOP ROD 3. Drill new 3/16" hole. Cutting is not required for standard 7', 8' or 10' doors. 1. Calculate top rod cut. *Use the bottom latch bolt as a drill guide for new hole. If no bottom latch is present drill hole centered 1/4”...