7.
Set at Fill time sample bottle (Shuttle) the fill time of the sample bottle.
1.
Set the value with the keypad or use the button
The default value is 20 sec.
•
2.
Button Save.
8.
Set at Fill time sample bottle (one bottle) the fill time of the sample bottle (one bottle).
1.
Set the value with the keypad or use the button
The default value is 20 sec.
•
2.
Button Save.
5.4
Connecting the Shuttle Sampling Device
Ensure that the Shuttle sampling device is thoroughly cleaned before use. Give particular
attention to the milk tubes.
The Shuttle sampling device must be connected by tubing to the automatic milk system.
•
The lowest milk level in the system must be approximately 5 kg (11.02 lb).
•
The milk should be mixed (bubbling) before sampling each milking.
•
•
The milk delivery tube must deliver a reliable sample of the milk to be sampled, depending on the
model of spoon in use:
10 ml (0.34 oz).
•
18 ml (0.61 oz).
•
30 ml (1.01 oz).
•
50 ml (1.69 oz).
•
•
The excess milk delivered must be able to be extracted through the milk delivery tube by means of
vacuum, and in particular, without leaving any residual milk in the tube.
Operating Instructions
to lower or
to raise the value.
to lower or
to raise the value.
in n o vato rs in ag ric u ltu re
5-5
Need help?
Do you have a question about the Shuttle and is the answer not in the manual?