Problem
Sample volume is too large.
The valve in the spoon is spilling.
7-2
Possible cause
Examine if the serrated frame is straight
•
(see Examine the Serrated Frame).
•
The spoon is overfilled; milk is overflowing the
spoon.
Examine the period of milk delivery during
•
sampling.
Filler elbow pipe is too short.
•
Modify the volume of sample taken (see
•
Examine if the Float Chamber Contains the
Correct Volume).
The O-ring of the valve is worn.
•
Replace the O-ring.
•
The serrated frame is no longer in a level
•
position, causing the valve in the spoon to hit
the position plate and to open up.
•
Put the serrated frame in a level position
(see Examine the serrated Frame).