LELY Shuttle Operator's Manual page 54

Sampling device

Advertisement

Problem
Sample volume is too large.
The valve in the spoon is spilling.
7-2
Possible cause
Examine if the serrated frame is straight
(see Examine the Serrated Frame).
The spoon is overfilled; milk is overflowing the
spoon.
Examine the period of milk delivery during
sampling.
Filler elbow pipe is too short.
Modify the volume of sample taken (see
Examine if the Float Chamber Contains the
Correct Volume).
The O-ring of the valve is worn.
Replace the O-ring.
The serrated frame is no longer in a level
position, causing the valve in the spoon to hit
the position plate and to open up.
Put the serrated frame in a level position
(see Examine the serrated Frame).
in n o vato rs in ag ric u ltu re
Troubleshooting