OPERATION INFORMATION
PROGRAMMABLE HANDSWITCH OPERATION
To exit the menu without making a selection, wait until the height display appears again.
CHANGE THE HEIGHT DISPLAY
If the displayed value does not match the actual height of the table top, the display can be corrected as follows:
1. Press and hold the (Center/---- button) until "F" appears
2. Using the UP button cycle through the menu for "F2" and press the (Center/---- button)
3. Use the UP/DOWN buttons to adjust to the desired height display and press the (Center/---- button) to save.
To exit the menu without making a selection, wait until the height display appears again.
SAVE MEMORY POSITION
1. Move the table up or down to the desired height.
2. Press the center button/------ (in the display "P-" is shown)
3. Select a position by pressing one of the four number buttons, 1-4, (the display will show the setting as "P1").
4. The saved position is confirmed by a double click sound from the control box. The display shows the current table height.
Repeat steps to save a maximum of four different positions.
To exit the menu without making a selection, wait until the height display appears again.
RECALL MEMORY POSITION
Press and hold the desired memory button (1, 2, 3 or 4) the table moves from the current position into the saved position.
The button must be pressed until the position is reached. If the button is released, the table will stop short of the desired
height.
SENSITIVITY ADJUSTMENT FOR EXTERNAL COLLISION SENSOR
The sensitivity can be adjusted separately for the optional external sensor (STAND.GUARD G1), each for up and down
travel.
1. Go to the menu of the hand switch in accordance with the instructions.
2. Navigate with the arrow keys (
menu option 8, display shows:
menu option 9, display shows:
3. Confirm the selection by once again pressing the "Logo" key.
4. Use the arrow keys (
a. 0% (OFF)
b. 99% (very sensitive)
5. Pressing the "Logo" button again saves the displayed value. Alternatively, wait approx. 10 seconds to cancel the
function and to return to the menu.
Warning: The sensitivity of the external sensor should only be changed by trained personnel. By reducing the sensitivity, collisions may
possibly be detected later or not at all.
The factory-set default values in the controller were selected so that the collision forces are below 150N for a maximum of 5 seconds and
then only 25N. If the sensitivity is reduced, the approval according to EN ISO 12849-1 expires.
and
) to the...
F8
F9
for the external sensor (STAND.GUARD G1) drive up
F9
for the external sensor (STAND.GUARD G1) drive down
and
) to adjust the displayed sensitivity in % to the desired percentage:
(continued)
16
User Guide
or
to