SICK microScan3 Core I/O Operating Instructions Manual page 145

Safety laser scanners
Hide thumbs Also See for microScan3 Core I/O:

Advertisement

8016346/1NTM/2024-06-03 | SICK
Subject to change without notice
 
Devices with a max. protec‐
tive field range of 9.0 m
Scanning range of the refer‐
ence contour field
Scanning range of the con‐
tour detection field
Warning field range
Devices with a max. protec‐
tive field range of 4.0 m
Devices with a max. protec‐
tive field range of 5.5 m
Devices with a max. protec‐
tive field range of 9.0 m
Fields
Simultaneously monitored
fields
Field sets
Monitoring cases
Scanning angle
Protective field resolution
Response time
Devices with a max. protec‐
tive field range of 4.0 m
Devices with a max. protec‐
tive field range of 5.5 m
Devices with a max. protec‐
tive field range of 9.0 m
Scan cycle time
Devices with a max. protec‐
tive field range of 4.0 m
Devices with a max. protec‐
tive field range of 5.5 m
Devices with a max. protec‐
tive field range of 9.0 m
Generally necessary protective field supplement (TZ = tolerance zone of the safety laser
scanner)
Devices with a max. protec‐
tive field range of 4.0 m
Devices with a max. protec‐
tive field range of 5.5 m
Devices with a max. protec‐
tive field range of 9.0 m
Additional supplement
Z
 for reflection-based meas‐
R
urement errors
Distance of mirror rotational
axis (zero point of x and y
axis) to mounting surface on
rear side of device
microScan3 Core I/O
≤ 9.0 m, details:
see "Sensing range", page 152
Same as protective field range,
Same as protective field range,
≤ 40 m
≤ 40 m
≤ 64 m
≤ 8
≤ 4
≤ 8
≤ 2
275° (–47.5° ... 227.5°)
30 mm, 40 mm, 50 mm, 60 mm, 70 mm, 150 mm, 200 mm
≥ 70 ms, details:
see "Response times", page 150
≥ 70 ms, details:
see "Response times", page 150
≥ 90 ms, details:
see "Response times", page 150
30 ms or 40 ms (adjustable)
30 ms or 40 ms (adjustable)
40 ms or 50 ms (adjustable)
65 mm
65 mm
100 mm
350 mm
56 mm
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O
TECHNICAL DATA
see "Sensing range", page 152
see "Sensing range", page 152
13
1)
145