Ring and Call Waiting Tone Spec

IMPORTANT: Ring and Call Waiting tones do not work the same way on all
phones. When setting ring tones, consider the following recommendations:
Begin with the default Ring Waveform, Ring Frequency, and Ring Voltage.
If your ring cadence doesn't sound right, or your phone doesn't ring, change
your Ring Waveform, Ring Frequency, and Ring Voltage to the following:
-
Ring Waveform: Sinusoid
-
Ring Frequency: 25
-
Ring Voltage: 80Vc
Ring Waveform
Ring Frequency
Ring Voltage
CWT Frequency
Synchronized
Ring

Control Timer Values (sec)

Voice > Regional > Control Timer Values (sec)
Hook Flash Timer
Min
Cisco SRP500 Series Services Ready Platforms Administration Guide (SRP520 Models)
Waveform for the ringing signal. Choices are Sinusoid or
Trapezoid.
The default is Trapezoid.
Frequency of the ringing signal. Valid values are 10–100
(Hz). The default is 20.
Ringing voltage. Choices are 60–90 (V).
The default is 85.
Frequency script of the call waiting tone. All distinctive
CWTs are based on this tone.
The default is 440@-10.
If this is set to Yes, when the SRP is called, all lines ring at
the same time (similar to a regular PSTN line). After one line
answers, the others stop ringing.
The default is no.
Minimum on-hook time before off-hook qualifies as
hookflash. Less than this the on-hook event is ignored.
Range: 0. 1 –0.4 seconds.
The default is 0. 1 .