Initial Operation
6.4.4
Filter Settings
Index
Subindex Data type
0x2032 1
8 bytes
Uint16
Uint16
Uint32
6.4.5
Sample Time
Index
Subindex Data type
0x2036 1
Uint32
combiSENSOR KSB6430 PROFINET
Name
RW Filter Settings
Filter type
Reserved
Filter value
Name
RW Sample time interval
Description
0: No filter
1: Moving average
2: Arithmetic average
4: Median
Filter length: 2 / 3 / 4 / 5 / 6 / 7 / 8
Description
256: 3906.3 Hz
480: 2083.3 Hz
960: 1041.7 Hz
1920: 520.8 Hz
9600: 104.2 Hz
16000: 62.5 Hz
19200: 52.1 Hz
32000: 31.3 Hz
38400: 26 Hz