162 en | System Event Timers
19.8

Codepad Lockout Time

Item
Codepad Lockout
Time
All codepads are locked out for the programmed time if an invalid code is entered more
times than allowed by the code retry attempts programmed in Location 424. If the Codepad
Lockout Time is programmed as 0, codepad lockout does not occur.
Refer to
19.9

Siren Run Time

Item
Siren Run Time
The Siren Run Time determines how long the horn speaker/siren operates during an alarm.
You can program the Siren Run Time from 0 to 15 min in 1-min intervals.
19.10

Siren Sound Rate

Item
Siren Sound Rate
The Siren Sound Rate varies the frequency of the siren tone slowest (0) and to fastest (15).
The Siren Sound Rate does not change the frequency of the fire alarm tone.
19.11

Auto Arming Pre-Alert Time

Item
Auto Arming Pre-Alert Time
This location sets the time period during which the control panel warns you it is
automatically armed in AWAY Mode. The codepad beeps once every second until the Pre-
Alert Timer expires: the system then automatically arms itself in AWAY Mode. If you want the
system to automatically arm in STAY Mode 1, enable Option 4 in Location 496 (refer to
Consumer Options 1, page 169).
After the control panel is automatically armed in AWAY Mode or STAY Mode 1, Exit Time
starts. If a valid User Code is entered during the Pre-Alert Time, the Auto Arming Time
programmed in Locations 482 to 485 is extended by 1 hour.
If you want a programmable output to operate during the Auto Arming Pre-Alert Time, use
Output Event Type 0,5 Auto Arm Pre-Arming Alert Time.
2024-07 | V01 | F.01U.418.606
Location
Option
0478
0 = No lockout
1 – 15 = Lockout time 10 – 150 sec.
(Increments of 10 sec.)
Access Denied, page 135
Location
Option
0479
0 = No Siren time
1 – 15 = Siren time 1 – 15 min. (increments
of 1 min.)
Location
Option
0480
0 = Slowest frequency
15 = Fastest frequency
Location
0481
Option
0 = No alert time
1 – 15 = Alert time 5 – 75 min.
(increments of 5 min.)
Installation manual
Solution 4000 control panel
Default New
0
Default New
5
Default New
7
Default New
1