Solution 4000 control panel
13.19
Communication Options 2
Item
Communication Options
2
1 – Arm/Disarm Reports Only if Previous Alarm
When selected, an Disarm Report is transmitted to the base station receiver when the
system is disarmed after an alarm occurred. When the system is armed, an Arming Report is
transmitted. An Arm or Disarm Report does not report again until the system registers
another alarm.
For a partitioned control panel, an Arm/Disarm Report is sent only for the area in which the
alarm occurred.
Notice!
If the system is disarmed when an alarm occurs, only an Arm Report is sent the next time
i
the system is armed.
A User Code with a priority set to Always Send Arm/Disarm Reports overrides this feature
(Arm/Disarm Reports are always sent for that User Code).
2 – STAY Mode Arm/Disarm Reports Enable
Select this option if Arm/Disarm Reports are required when the system is armed in STAY
Mode 1 or STAY Mode 2.
If this option is selected, a Partial Arm Report is sent when the system is armed in STAY
Mode 1 or STAY Mode 2.
4 – Delay Siren until Transmission Complete
If this option is selected, horn speaker, bell, and strobe outputs are not activated until after
the control panel sends the message and the base station receiver sends a kiss-off back to
the control panel. If multiple messages are transmitted, the sirens are activated after the
last kiss-off is sent.
If a Codepad Panic, Codepad Fire, or Codepad Medical Alarm is activated, horn speaker,
bell, and strobe outputs operate immediately.
8 – Extend Time to Wait for Handshake from 30 to 60 Sec
By default, the control panel waits approximately 30 sec for receipt of a valid handshake
tone after it dials the monitoring station. The handshake tone indicates to the control panel
that it reached the monitoring station and can now transmit its messages. Selecting this
option extends this wait time from 30 sec to 60 sec.
13.20
Communication Options 3
Item
Communication Options
3
Bosch Security Systems B.V.
Location
Option
0178
1 = Arm/Disarm Reports only if alarmed
2 = STAY Mode Arm/Disarm Reports
Enable
4 = Delay siren until transmission
complete
8 = Extend handshake wait time from 30
to 60 sec.
Location
Option
0179
1 = Set DTMF dialing pluses to 1 digit/
sec
2 = Lockout telephone line fail alarm
4 = Reserved
8 = Reserved
Installation manual
Communication Information | en
Default New