Solution 4000 control panel
If this option is selected, the zone sends Restore Reports when the zone is restored. If this
option is not selected, the zone does not send Restore Reports when the zone is restored.
If a non-24-Hour zone is not restored when the system is disarmed, the system automatically
sends a Zone Restore Report for that zone. All 24-Hour zones send a Zone Restore Report
only when the zone is restored.
15.4.7
Zone Report Options
By default, a zone reports only to Receiver 1. The table below lists the reporting options for
the zone.
Option
0
1
2
3
4
5
6
7
15.4.8
Keyswitch Zone Options
The table below lists the options available to Keyswitch Zones. If you program a zone as a
keyswitch input (Zone Type 11), program the selected Keyswitch Zone options in the
location normally used for Zone Options 1.
Option
0
1
2
4
5
6
8
9
10
12
13
14
0 – Latching Arm and Disarm in AWAY Mode
Bosch Security Systems B.V.
Description
No reports allowed
Report to Receiver 1
Report to Receiver 2
Report to Receiver 3
Report to Receiver 4
Report to Receiver 1,2,3,4
Report to Receiver 1 (2,3,4 backup)
Report to Receiver 1 (2 backup) and Receiver 3 (4 backup)
Description
Latching arm and disarm in AWAY Mode
Latching arm in AWAY Mode
Latching disarm from AWAY Mode, STAY Mode1, or STAY Mode 2
Latching arm and disarm in STAY Mode 1
Latching arm in STAY Mode 1
Latching disarm from STAY Mode 1 or STAY Mode 2
Momentary arm and disarm in AWAY Mode
Momentary arm in AWAY Mode
Momentary disarm from AWAY Mode, STAY Mode1, or STAY Mode 2
Momentary arm and disarm in STAY Mode 1
Momentary arm in STAY Mode 1
Momentary disarm from STAY Mode 1 or STAY Mode 2
Installation manual
Zone Information | en 123
2024-07 | V01 | F.01U.418.606
Need help?
Do you have a question about the ICP-SOL4-P and is the answer not in the manual?