Midi Program Change - Yamaha PM 5000 Owner's Manual

Owner's manual
Hide thumbs Also See for PM 5000:
Table of Contents

Advertisement

Digital Control Section
● NRPN Control
In the PM5000 NRPN (Non-Registered Parameter
number) data can be used for the same control functions
as control change commands. NRPN is actually a subset
of the MIDI control change numbers (CC#99, 98), and is
commonly employed to allow system exclusive data
transfer between different devices. Because of their
special status, NRPN commands are omitted from the
control change commands (refer to the above chart).
The PM5000 panel controls can be controlled using
either control change or NRPN commands. The
parameters described below allow control change and
NRPN control to be independently enabled and disabled
as required. If both are enable control change commands
take priority.
NOT E
As with program change commands, control change commands
are transmitted and received via specific MIDI channels. The
transmit and receive MIDI channels specified by the following
parameters (TX CH, RX CH), however, do not directly affect
control change operation (they do affect NRPN and scene number
increment/decrement control which has independently
programmable transmission and reception).
NOT E
If the MUTE MASTER switches are assigned to direct scene
recall (page 71), MUTE MASTER control via control change
commands will be ignored. If the preview mode is active any
received control change or NRPN commands will affect the
currently active scene rather than the scene being previewed.
Also, continuous level variations produced by fade time
variations between scene changes will not be transmitted.
80
MIDI Program Change (Parameter No. U24)
Determines whether the PM5000 will transmit and
receive program change commands. The program
change table to be used is also specified here.
M I D I
P G M
1
Press [ENTER] after selecting the above display and
a display like the one shown below will appear. Use
the [INC] and [DEC] keys to select the required
setting, then press the [ENTER] key.
OFF:
Program change commands will not be transmitted or
received.
P C : O F F
ON:
The corresponding program change command will be
transmitted when a successful scene recall operation
has been executed, but no data will be transmitted
when an empty "NO DATA" scene is recalled.
P C : O N
LOCAL:
The corresponding program change command will be
transmitted whenever a scene recall operation is
performed, regardless of the results.
P C : L O C A L
2
Use the [INC] and [DEC] keys to select the program
change table to be used: either the pre-programmed
DEFAULT program change table, or the user-
programmable USER table.
DEFAULT:
The pre-programmed program change table.
D E F A U L T
USER:
A user-defined program change table configured via
the function described on page 83.
U S E R
C H G