STANDALONE
7.4.READING MODES
7.4.1.CARD READING ONLY
In this operating mode, reading by numerical code (PIN) is not possible.
7.4.2.CARD OR CODE READING (default value)
In this operating mode both card and numerical code opening are enabled.
7.5.DOOR OPENING TIME
7.5.1.STANDARD MODE (default value)
By default the reader opening time is 5 seconds.
Note:
By default the reader gives a 5s pulse opening time. It is recommended to install an automatic type door opener (one press unlocks the
door opener, which locks again when the door closes) or to vary the opening time in the configuration.
7.5.2.CUSTOM MODE
This mode allows you to set the opening time to a duration between 1 and 99 seconds.
Note: It is recommended to use an automatic opener (with memory) to avoid the need to modify the opening time. Suggested lock
release: CV-24/DC.
7.6.READER OPERATING MODES
7.6.1.WIEGAND MODE OPERATION
Set the terminal to work in Wiegand operating as a slave.
See connection diagram in section 5.2.SLAVE READER.
7.6.2.STANDALONE MODE OPERATION (default value)
Set the terminal to work in Standalone.
See connection diagram in section 5.1.STANDALONE READER.
7.7.ANTI-PASSBACK FUNCTION
Anti-passback: A user will be able to exit if he has previously accessed, at the same time, he will not be able to access again if he has not
performed the exit reading. Requires the use of 2 terminals ( entrance reader/exit reader) for the same door.
See connection diagram in section 9.1.ANTI-PASSBACK MODE.
www.golmar.es
Enter administrator mode
*
MASTER CODE
(By default: 888888)
Enter administrator mode
*
MASTER CODE
(By default: 888888)
Enter administrator mode
*
MASTER CODE
(By default: 888888)
Enter administrator mode
*
MASTER CODE
(By default: 888888)
Enter administrator mode
*
MASTER CODE
(By default: 888888)
Enter administrator mode
*
MASTER CODE
(By default: 888888)
Enter administrator mode
*
MASTER CODE
(By default: 888888)
30
#
#
32
#
#
40
#
#
4
1-99
#
#
710
#
#
711
#
#
715
#
#
KEYBUS SE
7
Need help?
Do you have a question about the KEYBUS SE and is the answer not in the manual?
Questions and answers