  • Page 2: Table Of Contents

    Each time the power supply is restarted, or after a modification, the system will remain blocked during 30 seconds. Always use RG-59 or RG-11 coaxial cables. Never use coaxial antenna cable. In installations no longers than 100m., Golmar RAP-5130 cable can be used.
  • Page 3: System Characteristics

    SYSTEM CHARACTERISTICS DOOR PANEL INSTALLATION Microprocessed system with 3 common wires plus coaxial cable installation or 4 common wires mbedding box positioning. plus twisted pair (only for kits /SC). Fully compatible with 'Stadio' audio systems of 4 common wires installation. Unlimited number of door panels being not necessary the use of switching units.
  • Page 4 DOOR PANEL INSTALLATION DOOR PANEL INSTALLATION lace the embedding box. inking the push buttons modules. The maximum number of push buttons modules contained in a door panel is two, obtaining a maximum of 24 push buttons. Pass the wiring through the hole made in the bottom part Wire the push buttons modules with the main module as shown below.
  • Page 5 DOOR PANEL INSTALLATION DOOR PANEL INSTALLATION Coming from previous page escription of the configuration jumpers. escription of the configuration dip switch. Set to ON the switch number 2 for monitor or telephones The JP1 and JP2 configuration jumpers are placed near programming.
  • Page 6: Door Panel Fixing

    DOOR PANEL INSTALLATION POWER SUPPLY INSTALLATION lace the nameplate labels. nstalling the FA-PLUS and FA-PLUS/C power supplies. The power supply must be installed in a dry and 3,5 x 25 protected place. It's recommended to protect DIN-7971 the power supply by using a thermo-magnetic circuit breaker and to use a ground connection.
  • Page 7: Platea Plus Monitor

    MONITOR DESCRIPTION MONITOR DESCRIPTION escription of the Platea Plus monitor. unction push buttons. On-Off push button. After any monitor reset and during the next 45 seconds, all the monitor functions will be disabled, with the exception of call reception. 0000000000 Monitor Nº...
  • Page 8: El561 Module

    MONITOR ADJUSTMENTS MONITOR CONNECTOR DESCRIPTION L561 module for video installations escription of the RCPL-Plus with twisted pair cable. monitor connector. Locate the CN4 connector, that's placed in the monitor base. Remove the existing jumper and plug the EL561 module. NOTE: on this type of installations the EL560 module must be plugged in the CN4 connector of the panel (page 7).
  • Page 9: Monitor Installation

    MONITOR INSTALLATION MONITORS PROGRAMMING ix the monitor connector to the wall. rogramming the monitors. Avoid to place the monitor near to heating sources, Set to ON the switch number 2 of the configuration dip switch, that's in dusty locations or smoky environments. accessible by opening the terminal connector protection cover.
  • Page 10: Description

    TELEPHONE DESCRIPTION TELEPHONE DESCRIPTION erminal connector description. escription of the T-940 Plus telephone. – positive, ground. A , D : audio, digital communication. Telephone handset. INT : intercom. Speaker grille. SA : auxiliary calling device output. Microphone hole. HZ- : door bell push button input.
  • Page 11: Programming

    TELEPHONES PROGRAMMING INSTALLATION DIAGRAMS rogramming the telephones. onnexion of an a.c. lock release. As it is described on page 9, the lock releases to be connected to the door panel Set to ON the switch number 2 of the configuration dip switch, that's must be d.c.
  • Page 12 INSTALLATION DIAGRAMS * Take off JP1 jumper of all the distributors except in the last one. D4L-PLUS ideo installation with coaxial cable. Malla Malla The installation diagram shows the connection of a video system with one or several door panels for the same building. If the system has one door panel only, override the wiring to the second door panel.
  • Page 13 INSTALLATION DIAGRAMS EL561 EL561 * Take off JP1 jumper of all the distributors except in the last one. ideo installation without coaxial cable. D2L-Plus/2H The installation diagram shows the connection of a video system with one or several door panels for the same building. If the system has one door panel only, override the wiring to the second door panel.
  • Page 14: Audio Installation

    INSTALLATION DIAGRAMS T-940 Plus T-940 Plus udio installation. The installation diagram shows the connection of an audio system with one or several door panels for the same building. If the system has one door panel only, override the wiring to the second door panel. If the system has more than one door panel, wire the second panel as shown on the diagram.
  • Page 15: Optional Connections

    OPTIONAL CONNECTIONS OPTIONAL CONNECTIONS xternal lock release activation. ntercom function. The lock release can be activated at any moment Platea Plus monitor and T-940 Plus telephone have intercom facility between two units of the by using an external push button, that must be same apartment .
  • Page 16: Door Bell Push Button Connection

    OPTIONAL CONNECTIONS TROUBLESHOOTING HINTS An easy way to check that the system is working properly is to disconnect the wiring from the door ctivation of a second camera. panel and to check a monitor or telephone directly connected to the door panel. No shortcircuit will damage the connected units, with the exception of a shortcircuit between CTO and ' ' monitor or distributor terminals.
  • Page 17 Golmar se reserva el derecho a cualquier modificación sin previo aviso. Golmar se réserve le droit de toute modification sans préavis. Golmar reserves the right to make any modifications without prior notice.