Omron Z550 Operation Manual page 43

Multi-dimensional sensor
Hide thumbs Also See for Z550:
Table of Contents

Advertisement

A list of outputs appear.
2.
Select the output for which [Step: 2 pts] is to be set.
In this example, select [OUT1].
The selections for measurement item appear.
3.
Select [Step: 2 pts].
The bottom face line setting screen appears.
4.
Specify the start and end lines of the bottom face.
Left/Right key: Moves the cursor.
(Press these keys together with the SHIFT Key to move
the cursor quickly.)
ENT Key: Selects the setting.
ESC Key: Cancels the setting.
The characteristic quantity setting screen appears.
5.
Select the measurement point for the bottom-face
measurement.
Select which position (peak, bottom, or average) within the
specified region will be the measurement point.
The cross cursor indicating the measurement point moves
according to the selection; select the position while
monitoring the image.
In this example, select [Average].
Basic Operations
Scn 0
Set
OUT0:Height
OUT1:
OUT2:
OUT3:
OUT4:
OUT5:
OUT6:
OUT7:
Measrmnt item
Height
Step: 2 pts
Step: 3 pts
Edge position
Width
Edge center
Peak/bottom
Angle
Average
Peak
Bottom
SECTION 2
Peak
Bottom
Z550
41
Operation Manual