Specify the Controller communication settings.
The default communications settings at the shipment are as shown in the following table.Use the default
settings under normal circumstances.
Setting communication specifications p.196
Item
Baud rate
Data length
Parity
Stop bits
Delimiter
Flow control
3.
Start the Hyper Terminal program on the PC and specify the communication settings as follows.
The same communication settings must be used for both the Controller and the modem on the PC side.
Item
Bits per second (B)
Data bits (D)
Parity
Stop bits
Flow control
* The flow control is not performed because the XMODEM protocol is used for the communication.
4.
Once the preparations have been completed on the
PC, enter the Tools mode.
Setting value
38400 (bps)
8 (bit)
None
1 (bit)
CR
None*
Setting value
38400 (bps)
8 (bit)
None
1 (bit)
None*