SECTION 6
Communication with External Devices
Perform the following procedure in order to set and fix the optimum sensitivity for the workpiece
to be measured.
Example:
Input
Output
Input
Output
SENSM
Function 1......Sets the sensitivity adjustment method to [Multi] and obtains the optimum
Input
Output
Z550
206
Operation Manual
SENS
Delimiter
17
Delimiter
The optimum sensitivity is 17.
SENS 15 19 170
Delimiter
OK
Delimiter
The sensitivity level is automatically adjusted in the range between 15 and 19 with a
target light reception level of 170.
sensitivity for the workpiece.
SENSM <Priority item>
Specify either 0 or 1 for the priority item.
Priority item
0
Priority on dynamic range
1
Priority on sampling period (default selection when
setting is omitted)
Command executed correctly
Command not executed correctly : ER
Delimiter
Meaning
: Sensitivity lower limit, sensitivity upper limit
Delimiter
Delimiter