Table 4.2 Constants that Are Set as Required
Name
Select stopping method when stop command is
sent.
Stopping method
0: Deceleration to stop
selection
1: Coast to stop
2: DC braking stop
3: Coast to stop with timer
Carrier fre-
quency selection
The carrier frequency is set low if the motor cable
is 50 m or longer or to reduce radio noise or leak-
age current.
Carrier fre-
quency selection
for open-loop
vector control 2
Frequency refer-
ences 1 to 4 and
Set the required speed references for multi-step
jog frequency ref-
speed operation or jogging.
erence
FM and AM ter-
Adjust when an instrument is connected to the FM
minal output gain
or AM terminal.
If using the dynamic brake option (braking resis-
Stall prevention
tor, Braking Resistor Units, and Braking Units), be
selection during
sure to set constant L3-04 to 0 (disabled) or 3
deceleration
(enabled with braking resistor).
Description
Setting
Factory
Page
Range
Setting
5-10
0 to 3
0
6-13
Depends
on capac-
ity, volt-
1 to F
5-23
age, and
control
mode.
Depends
1 to 4
on kVA
5-25
setting.
d1-01 to
d1-04:
5-24
0 to 400.00 Hz
0.00 Hz
d1-17:
6.00 Hz
H4-02:
1.00
0.00 to 2.50
5-45
H4-05:
0.50
5-52
0 to 3
1
6-23
6-9