DROOP Control: b7
User constants for droop functions are shown in the following table.
Name
Con-
stant
Display
Number
Droop control
Sets the slip as a percentage
gain
of maximum frequency when
the maximum output fre-
quency is specified and the
b7-01
rated torque occurs.
Droop Quan-
Droop-control is not per-
tity
formed when the setting is
0.0.
Droop control
Droop control responsive-
delay time
ness constant
b7-02
When hunting or oscillation
Droop Delay
occurs, increase the value.
Time
Setting
Factory
Description
Range
Setting
0.0 to
0.0%
100.0
0.03 to
0.05 s
2.00