Name
Con-
Description
stant
Display
Number
Operation
Used to set the method of
selection
operation when the fre-
for setting
quency reference input is less
E1-09 or
than the minimum output fre-
less
quency (E1-09).
0: Run at frequency reference
(E1-09 not effective).
b1-05
1: STOP (Frequencies below
E1-09 in the coast to stop
state.)
Zero-Speed
2: Run at min. frequency.
Oper
(E1-09)
3: Run at zero speed (Fre-
quencies below E1-09 are
zero)
Read
Used to set the responsiveness
sequence
of the control inputs (forward/
input twice
reverse and multi-function
inputs.)
b1-06
0: Two scans every 2 ms (Use
for fast responses.)
Cntl Input
1: Two scans every 5 ms (Use
Scans
for possible malfunction
due to noise.)
Operation
Used to set the operation mode
selection
by switching to the Remote
after
mode using the Local/Remote
switching to
Key.
remote
0: Run signals that are input
mode
during mode switching are
b1-07
disregarded. (Input Run
signals after switching the
mode.)
LOC/REM
1: Run signals become
RUN Sel
effective immediately after
switching to the Remote
mode.
Run com-
Used to set an operation inter-
mand selec-
lock in programming modes.
tion in
0: Cannot operate.
program-
b1-08
1: Can operate (Disabled
ming modes
when Digital Operator is
set to select run command
RUN CMD
(when b1-02 = 0).
at PRG
* The setting range is 0 or 1 for flux vector control and open-loop vector control 2.
Change
during
Setting
Factory
Range
Setting
Opera-
V/f
tion
0 to 3
0
No
No
0 or 1
1
No
A
0 or 1
0
No
A
0 or 1
0
No
A
User Constant Tables
Control Methods
MEMO
Open
Open
BUS
V/f
Loop
Flux
Loop
Regis-
with
Vec-
Vec-
Vec-
ter
PG
tor
tor
tor
1
2
No
No
A
No
184H
A
A
A
A
185H
A
A
A
A
186H
A
A
A
A
187H
Page
6-9
-
-
-
11
5-