Omron VARISPEED G7 Instruction Manual page 132

Hide thumbs Also See for VARISPEED G7:
Table of Contents

Advertisement

Name
Con-
stant
Display
Number
Frequency
The frequency reference
reference 12
when multi-step speed refer-
d1-12
ences 1, 2, and 4 are ON for
Reference 12
multi-function inputs.
Frequency
The frequency reference
reference 13
when multi-step speed refer-
d1-13
ences 3 and 4 are ON for
Reference 13
multi-function inputs.
Frequency
The frequency reference
reference 14
when multi-step speed refer-
d1-14
ences 1, 3, and 4 are ON for
Reference 14
multi-function inputs.
Frequency
The frequency reference
reference 15
when multi-step speed refer-
d1-15
ences 2, 3, and 4 are ON for
Reference 15
multi-function inputs.
Frequency
The frequency reference
reference 16
when multi-step speed refer-
d1-16
ences 1, 2, 3, and 4 are ON
Reference 16
for multi-function inputs.
Jog frequency
The frequency reference
reference
when the jog frequency refer-
d1-17
ence selection, FJOG com-
Jog
mand, or RJOG command is
Reference
ON.
Note The unit is set in o1-03 (frequency units of reference setting and monitor). The default for o1-03 is 0 (increments of 0.01 Hz).
* The setting range is 0 to 66.0 for open-loop vector control 2.
Reference Limits: d2
User constants for frequency reference limits are shown in the following table.
Name
Con-
stant
Display
Number
Frequency
Set the output frequency
reference
upper limit as a percent, tak-
upper limit
d2-01
ing the max. output frequency
Ref Upper
to be 100%.
Limit
Frequency
Sets the output frequency
reference
lower limit as a percentage of
lower limit
d2-02
the maximum output fre-
Ref Lower
quency.
Limit
Master speed
Set the master speed refer-
reference
ence lower limit as a percent,
lower limit
d2-03
taking the max. output fre-
Ref1 Lower
quency to be 100%.
Limit
Setting
Factory
Description
Range
Setting
0.00 Hz
0.00 Hz
0.00 Hz
0 to
400.00
*
0.00 Hz
0.00 Hz
6.00 Hz
Setting
Factory
Description
Range
Setting
0.0 to
100.0%
110.0
0.0 to
0.0%
110.0
0.0 to
0.0%
110.0
User Constant Tables
Control Methods
Change
Open
during
V/f
Loop
Flux
Opera-
V/f
with
Vec-
Vec-
tion
PG
tor
tor
1
Yes
A
A
A
A
Yes
A
A
A
A
Yes
A
A
A
A
Yes
A
A
A
A
Yes
A
A
A
A
Yes
Q
Q
Q
Q
Control Methods
Change
Open
during
V/f
Loop
Flux
Opera-
V/f
with
Vec-
Vec-
tion
PG
tor
tor
1
No
A
A
A
A
No
A
A
A
A
No
A
A
A
A
MEMO
Open
BUS
Loop
Page
Regis-
Vec-
ter
tor
2
A
28DH
-
A
28EH
-
A
28FH
-
A
290H
-
A
291H
-
4-6
Q
292H
6-74
MEMO
Open
BUS
Loop
Page
Regis-
Vec-
ter
tor
2
6-30
A
289H
6-69
6-30
A
28AH
6-69
6-30
A
293H
6-69
27
5-