Multi-function Contact Outputs: H2
User constants for multi-function outputs are shown in the following tables.
Con-
stant
Number
Terminal M1-
M2 function
selection
H2-01
(contact)
Term M1-M2
Sel
Terminal M3-
M4 function
selection
(open collec-
H2-02
tor)
Term M3-M4
Sel
Terminal M5-
M6 function
selection
(open collec-
H2-03
tor)
Term M5-M6
Sel
Terminal P3
function
selection
H2-04
(open collec-
tor)
Term P3 Sel
Terminal P4
function
selection
H2-05
(open collec-
tor)
Term P4 Sel
-48
5
Name
Description
Display
Multi-function contact output
Multi-function contact output
1
Multi-function contact output
2
Multi-function contact output
3
Multi-function contact output
4
Control Methods
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
tion
0 to 37
0
No
A
0 to 37
1
No
A
0 to 37
2
No
A
0 to 37
6
No
A
0 to 37
10
No
A
MEMO
Open
Open
BUS
V/f
Loop
Flux
Loop
Regis-
with
Vec-
Vec-
Vec-
ter
PG
tor
tor
tor
1
2
A
A
A
A
40BH
A
A
A
A
40CH
A
A
A
A
40DH
A
A
A
A
40EH
A
A
A
A
40FH