C-6 Discrete Input Point Object (Class 0X08); C-7 Discrete Output Point Object (Class 0X09) - Omron MX2 DEVICENET OPTION BOARD User Manual

Mx2 devicenet option board
Table of Contents

Advertisement

Discrete Input Point Object (Class 0x08)
C-6
Discrete Input Point Object (Class 0x08)
Supported Service Codes
Object Details
Table C-11 Discrete Input Point Object - Object Details
Instance
Attribute
(hex)
(hex)
01 to 07
03
Value
(See
Note)
69
Override
C-7
Discrete Output Point Object (Class 0x09)
Supported Service Codes
Object Details
Table C-13 Discrete Output Point Object - Object Details
Instance
Attribute
(hex)
(hex)
01 to 03
03
Value
(See
note)
Table C-10 Discrete Input Point Object - Supported Service Codes
Service Code No. (hex)
0E
10
Name
Read input point value
0: Off
1: On
Override input point value
0: Off
1: On
Note
The instance 1 to 7 correspond to the MX2-A@ inverter input terminal [1] to
[7].
Table C-12 Discrete Output Point Object - Supported Service Codes
Service Code No. (hex)
0E
10
Name
Control the output point value
0: Off
1: On
Note
The instance 1 to 3 correspond to the MX2-A@ inverter output terminals
respectively output [11], output [12] and alarm relay contacts (AL0,1,2).
Get attribute single
Set attribute single
Content
Setting
range
----
----
Get attribute single
Set attribute single
Content
Setting
range
----
APPENDIX C
Service
Default
Get
Set
----
Yes
No
BOOL
----
Yes
Yes
BOOL
Service
Default
Get
Set
----
Yes
Yes
BOOL
Size
Size
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3g3ax-mx2-drt-e

Table of Contents