E3X-DA44-S Order fiber amplifier connector E3X-CN_ separately For fiber amplifiers with these functions and connecting with M8 connector, order the fiber amplifier connector models above and the pigtail connector E3X-CN21-M3J-2 with 30cm PVC cable and M8 plug. Fiber amplifier connectors...
Page 2
Output 1: ON Output 1: ON Output 2: OFF Output 2: ON The two outputs can be used to detect two different light levels Triggering on single or double signal edges Active-threshold control (ATC) Without ATC: malfunction caused by temperature drift, pollution or condensation...
Incident level + threshold or user specific The reverse polarity protection for the pre-wired and fiber amplifier connector models is for the power supply and the output. For M8 connector models the reverse polarity protection is for the power supply.
Page 4
1,800 1,350 E32-T17L 8,000 20,000 20,000 20,000 20,000 The sensing distances with M8 connector models E3X-DA[]3-S and E3X-DA@4-S are approximately 50% of the exemplary values measured with E3X-DA51-S. Reflective Models (Unit: mm) High-resolution High-speed Super-high- Type Tough Mode Standard Mode...
Note: 1 . Operation with area settings is as follows: LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2. DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2.
OFF when output is OFF. Use to select SET or RUN Mode. Safety Precautions To ensure safe operation, be sure to read and follow the Instruction Manual provided with the Sensor. • Operation at Power OFF WARNING A pulse may be output when the power supply is turned OFF. Turn...
Page 7
• EEPROM Writing Error insertion marks on the side of the Amplifier Unit, and lower the lock If the data is not written to the EEPROM correctly due to a power fail- lever. ure or static-electric noise, initialize the settings with the keys on the Amplifier Unit.
Page 8
(Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Amplifier Units Pre-wired Models Operation indicator (1ch) Operation indicator (2ch) E3X-DA21-S E3X-DA51-S Vinyl-insulated round cable Main display Sub-display Standard length: 2 m * Cable Specifications 4-dia., 5-conductor (Conductor...
Page 9
Operation indicator (1ch) Operation indicator (2ch) E3X-DA7-S E3X-DA9-S Main display Sub-display *1. The Mounting Bracket can With Mounting Bracket Attached also be used on this side. *2. Cable Diameters 3.9 × 3 = 11.7 32.8 E3X-CN21 4.0 dia. 29.8 (4 conductors) 3.9 ×...
Page 10
E3X-DA44-S Main display Sub display With Mounting Bracket Attached E3X-DA13-S 32.78 3.9x3=11.7 *1. The Mounting Bracket can 29.8 E3X-DA43-S also be used on this side. 15.13 3.9x3=11.7 *2. Connector size B *1 12.15 3.25 Optical communication position M8 *2 Two, 2.4 dia.
Page 12
This is not intended to be an exhaustive list or reproducing this document in any manner, for any other purpose. of all possible uses of the products, nor is it intended to imply that the If copying or transmitting this document to another, please copy or uses listed may be suitable for the products: transmit it in its entirety.