Basic Format of Explicit Messages
Example 3:
Writing BOOL Object
ForceFault/Trip
Example 4:
Read INT SpeedActual
72
Response:
No. of bytes received
Source node address
The latest trip of the inverter has been caused by E62 (value 3E Hex). This is
Force fault/trip from the option board.
Parameter:Class 29 Hex, Instance 01 Hex, Attribute 11 Hex
Command:
Destination node address
Response:
No. of bytes received
Source node address
Parameter:Class 2A Hex, Instance 01 Hex, Attribute 07 Hex
Command:
Destination node address
Response:
No. of bytes received
Source node address
The actual speed is read as 10.0 Hz (0064 Hex). Please note the swapping of
the data following CIP data type encoding.
03
8E
10
29
Service code
Class ID
02
90
0E
2A
Service code
Class ID
04
8E
APPENDIX E
3E
Data
Service code
01
11
01
Data
Attribute ID
Instance ID
Service code
01
07
Attribute ID
Instance ID
64
00
Data
Service code

Hide quick links: