Omron MX2 DEVICENET OPTION BOARD User Manual page 81

Mx2 devicenet option board
Table of Contents

Advertisement

Control Supervisor Object (Class 0x29)
Note
The following table shows the conversion between the MX2 Error or Trip code
and the CIP Fault and Warning codes.
Table D-5 Error Code Conversion
MX2 Error/Trip code
Code
E01
Over-current event while at con-
stant speed
E02
Over-current event during deceler-
ation
E03
Over-current event during acceler-
ation
E04
Over-current event during other
conditions
E05
Overload protection
E06
Braking resistor overload protec-
tion
E07
Over-voltage protection
E08
EEPROM error
E09
Under-voltage error
E10
Current detection error
E11
CPU error
E12
External trip
E13
USP
E14
Ground fault
E15
Input over-voltage
E16
Momentary electricity failure pro-
tection
E20
Temperature error with cooling fan
frequency lowering
E21
Inverter thermal trip
E22
CPU error
E24
Phase Failure
E25
Main circuit error
E30
Driver error
E35
Thermistor
E36
Braking error
E37
Safe Stop
E38
Low-speed overload protection
E40
Operator connection
E41
Modbus communication error
E43
EzSQ invalid instruction
E44
EzSQ nesting count error
E45
EzSQ instruction error
E50
EzSQ user trip (0 to 9)
...59
E60
Option error (inverter communica-
tions error)
E61
Option error (Duplicated MAC ID)
E62
Option error (External trip)
E63
DRT/CRT Communication lost /
idle
E64
Illegal flexible mapping
E65
Option error (reserved)
...68
Name
Code
2200 Current Inside the Device
2214 Overcurrent during Slowdown
2213 Overcurrent during Startup
2200 Current Inside the Device
2220 Continuous Overcurrent
7112 Brake Chopper overcurrent
3210 Overvoltage inside the device
6320 Parameter Error
3220 Undervoltage inside the Device
5210 Measurement Circuit
6100 Internal Software
9000 External Malfunction
9000 External Malfunction
2120 Short to Earth
3110 Mains overvoltage
3120 Mains undervoltage
4000 Temperature
4200 Device Temperature
5000 Device Hardware
3130 Phase Failure
5410 Output Stages
5400 Power section
7300 Sensor
9000 External Malfunction
9000 External Malfunction
2221 Continuous Overcurrent no1
5300 Operator control circuit
7500 Communication
6200 User Software
6200 User Software
6200 User Software
6200 User Software
7510 Serial Interface No 1
7510 Serial Interface No 1
7510 Serial Interface No 1
7510 Serial Interface No 1
6320 Parameter error
7510 Serial Interface No 1
APPENDIX D
CIP Fault and Warning Code
Name
67

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3g3ax-mx2-drt-e

Table of Contents