Accessing Parameters
Step 3
Step 4
Step 5
Table 41 Parameter Processing Message Area-Reading PNU915.3
Read element value in array task
Output area [hex] 6
Word offset
Function
AK
Input area [hex]
4
Task success (WORD element) response
Read value (Modbus address mapped into PZD3)
Changing an Option Board array element: To change Option Board param-
eter element 915.3 (Modbus address mapped into PZD3) to 1F01h (Coil data
0):
Table 42 Parameter Processing Message Area-Changing PNU915.3
Change WORD element value in array Write value
Output area [hex] 7
Word offset
Function
AK
Input area [hex]
4
Task success (WORD element) response
Storing changed parameter(s): To store changed parameter(s) in non-vola-
tile memory, write a 1 to Option Board parameter 971:
Table 43 Parameter Processing Message Area-Initiating NV Store
Change WORD parameter value task
Output area [hex] 2
Word offset
Function
AK
Input area [hex]
1
Task success (WORD parameter) response
Resetting the Option Board: To reset the Option Board, write a 2 followed by
a 1 to Option Board parameter 972:
Table 44 Parameter Processing Message Area-Prepare Reset
Change WORD parameter value task
Output area [hex] 2
Word offset
Function
AK
Input area [hex]
1
Task success (WORD parameter) response
Without changing AK or PNU, set PWE=1
Parameter number 915
Element at index 3
393
03
00
+0
+1
PNU
IND
-
393
03
00
Parameter number 915
Element at index 3
393
03
00
+0
+1
PNU
IND
-
393
03
00
Parameter number 971
3CB
00
00
+0
+1
PNU
IND
-
3CB
00
00
Parameter number 972
3CC
00
00
+0
+1
PNU
IND
-
3CC
00
00
Section 4-5
0000
0000
+2
+3
PWE
0000
0000
0000
1F01
+2
+3
PWE
0000
0000
Write
0000
0001
+2
+3
PWE
0000
0000
Write
0000
0002
+2
+3
PWE
0000
0000
29