Option Board Specifications - Omron 3G3AX-MX2-PRT-E User Manual

Mx2 profibus option board
Hide thumbs Also See for 3G3AX-MX2-PRT-E:
Table of Contents

Advertisement

Option Board Specifications

1-1-3
Inverter Safety (ISO 13849-1)
1-2
Option Board Specifications
Table 1 Option Board Specifications
Item
Unit type
Model
Dimensions (W x H x D)
Weight
Ambient operating tempera-
*1
ture
Ambient operating humidity
Ambient storage temperature
Vibration resistance
Dielectric strength
Conformance to EMC and
Electrical safety standards
Enclosure rating
Indicators
PROFIBUS connector
Applicable standards
Protocol type supported
PROFIBUS Unit type
PROFIBUS Media type
PROFIBUS Connector
Certificate
Unit device address range
Baud rates supported
Note 1
2
If these characters are absent, your Inverter does not support the
3G3AX-MX2-PRT-E, so please contact your local OMRON representative.
An MX2-A@ Inverter provides a Gate Suppress function to perform a safe
stop according to the EN60204-1, stop category 0. The 3G3AX-MX2-PRT-E
Option Board has been designed not to interfere with this safety function.
Note
The 3G3AX-MX2-PRT-E is not a safety device and does not implement any
safety protocols such as PROFIsafe
MX2 Series Option Card
3G3AX-MX2-PRT-E
68 x 58 x 45 mm
170g (typical)
-10 to 55°C (no icing or condensation)
20 to 90%RH
-20 to 65°C (no icing or condensation)
2
5.9m/s
(0.6G) at 10...55Hz
500 VAC (between isolated circuits)
EN61800-3: 2004 (2004/108/EC) Second environment, Category C3
EN61800-5-1: 2007 (2006/95/EC) SELV
IP 20
4 LEDs, indicating Option Board and PROFIBUS status:
Option Board Status:
PROFIBUS Status:
9-pin sub-D female connector (#4/40 UNC thread)
IEC 61158 Industrial communication networks - Fieldbus specifications
PROFIBUS DP
PROFIBUS DP-V1, Class 2 (MSAC2 acyclic messaging)
PROFIBUS DP-V1 Slave
RS-485, galvanically isolated from the MX2-A
9-pin sub-D female connector (#4/40 UNC thread)
Termination according to EN50170 provided by the cable connector
Test Specification for PROFIBUS DP Slaves, Version 3.0
DP-V0
0 ~ 125, set with inverter parameter P180
Automatically detected from:
9.6 kbit/s
187.5 kbit/s
6 Mbit/s
The derated- or ambient operating temperature of the MX2-A@ Inverter takes
precedence over that of the Option Board.
Specification
RUN (Green)
ERR(Red)
BF (Red)
COMM (Green)
@
DP-V1
Physical Layer
19.2 kbit/s
45.45 kbit/s
500 kbit/s
1.5 Mbit/s
12 Mbit/s
Section 1-2
Inverter
93.75 kbit/s
3 Mbit/s

Advertisement

Table of Contents
loading

Table of Contents