Before installation
E L E C T R I C A L W I R I N G C O N S I D E R AT I O N S
Take into consideration this section before starting wiring
the connections of the Charge Point.
1 — E L E C T R I C A L P R O T E C T I O N S
Charge Point may not include elements of electrical protection. If this equipment has internal
electrical protections, they are installed for each socket-outlet for the protection of the user
against an electrical failure, according to the international standard IEC 61851-1:2017.
The chargers equipped with Type A RCDs require an additional RCD installed upstream in order
to ensure the whole installation is compliant with the standard IEC 60364-7-722. This RCD shall
be of Type B or Type A with additional protection for DC leakage of 6mA (RCD-DD) according to
the IEC 62955.
In order to guarantee the total protection of the users and the installation (power supply line
included) in front of any electrical hazard, it is mandatory to install a main circuit breaker (MCB)
and a residual current device (RCD) upstream of the charger. These electrical protections and
the rest of the installation have to be aligned with the local and national rules. The selectivity of
the protections has to be guaranteed at all times.
2 — P O W E R S U P P LY L I N E D I M E N S I O N I N G
The dimensioning of the input power supply line of the Charge Point shall be checked by a
qualified electrician. Note that various factors such as cable length between distribution board
and Charge Point and maximum output current of the Charge Point may have influence on the
selected cable.
In such cases, increasing the cable cross-section is required to adapt the temperature resistance
of the power supply line.
3 — M A X I M U M O U T P U T C U R R E N T
Please refer to the TECHNICAL DATA section to consult the default factory settings of maximum
output current of the Charge Point.
If the power supply is less than maximum output current and adjustment to a lower nominal
current needs to be performed, please refer to the USER MANUAL.
Depending on the model this value may vary.